Fla. Admin. Code Ann. R. 61-41.009 - Design Plan and Systems Approval
(1)
General. A final design plan approval shall be contingent upon compliance with
these rules and the building codes specified in Rule
61-41.004, F.A.C. The
manufacturer shall submit plans for approval by the Agency. The Agency
reviewing the plans shall notify a manufacturer of any apparent errors or
omissions and request any additional information necessary to evaluate the
plans submitted within thirty days of receipt of the plans. The Department
shall have the authority to seek revocation of a plan approval by an Agency if,
through monitoring activities, the Department discovers that the plans fail to
comply with the standards adopted herein.
(2) Approved Plans. Plans are approved for
all code related items installed at the manufacturing facility in accordance
with Sections 553.37(1) and
553.38, F.S. All code related
items not installed at the manufacturing facility shall be clearly noted on the
plans cover page as "Items to be site installed and subject to local code
review and compliance."
(3)
Completed sets of design plans and specifications, prepared by an architect or
engineer licensed to practice in the State of Florida, except as exempted by
Florida law; supporting calculations and any required test results for each
system and prototype to be approved. Based on compliance with the codes in Rule
61-41.004, F.A.C., the Agency
shall approve or disapprove the manufacturer's submittal. If the submittal is
approved, the Agency shall affix a stamp authorized by the Department on each
sheet. Plans drawn to a scale less than 1/8'' to the foot are not acceptable.
Plans shall be legible for reproduction purposes, including vergiage
(4) System Approval. The manufacturer may
submit through the Agency for Department approval a system of construction
which may include any or all elements of building systems such as structural,
mechanical, plumbing, and electrical elements or components. Such submission
shall include all documents and data providing complete information necessary
for evaluation of the systems' performance and capabilities for its intended
use.
(5) The Agency shall conduct a
review of each set of documents submitted, including the plans, specifications
and design calculations, for compliance with the appropriate code and this part
and shall utilize a checklist. The plans review and the checklist utilized
therewith shall at a minimum contain the plan review requirements of the
Florida Building Code, adopted pursuant to Rule
61G20-1.001, F.A.C.:
(6) Plan Approval Expiration - Upon revision
of the building codes adopted herein, plan approvals shall expire upon the
effective date of the revisions unless the manufacturer files with the
department a sworn statement by an Agency that the plans as previously approved
have been reviewed and are in compliance with the revisions to the adopted
codes. The Agency shall ensure that it has obtained, and retains as a public
record, all data and information necessary to support that sworn statement
consistent with rules regulating the practice of engineering or architecture or
both engineering and architecture. This rule is not intended to provide a
defense for Agencies from any charge of unlicensed practice of engineering or
architecture. The Agency shall transmit plans electronically through the
Building Code Information System to the Department.
(7) Manufacturer's Component Data Plate. Each
component or package of like components shall contain a manufacturer's data
plate which indicates the limiting characteristics and design criteria of such
components for determining how they are to be installed and utilized within
their capabilities. Such data plate information shall be approved by the
Agency.
(8) Manufacturer's Modular
Data Plate. The manufacturer shall install on all manufactured (modular)
buildings and components prior to leaving the manufacturing plant a data plate
which shall be permanently affixed on or about the electrical panel and which
shall contain, but not be limited to, the following design information when
applicable.
(a) Name and address of
Manufacturer;
(b) Name of Third
Party Agency;
(c) Manufacturer
Certification Number;
(d) Date of
Manufacturer;
(e) Date of
Alteration;
(f) Number of
Modules;
(g) Construction Type as
defined in Chapter 6 of the Code;
(h) Occupancy Use Classification in
accordance with Chapter 3 of the Code;
(i) Design Occupant Load;
(j) Serial Number;
(k) Agency Plan Number;
(l) Standard Plan Approval Number;
(m) Maximum Floor Load (pounds per square
foot), Live Load and Dead Load;
(n)
Roof Load; Live Load and Dead Load;
(o) Wind Velocity Rating;
(p) "U" rating of Floor, Wall, and
Roof;
(q) Limitations of the plan
approval by the Agency;
(r) If an
automatic sprinkler system is provided, whether the sprinkler system is
required; and
(s) Any special
stipulations and conditions of the building
permit.
Notes
Rulemaking Authority 553.37(2) FS. Law Implemented 553.37(2) FS.
New 1-17-72, Amended 2-23-75, 3-1-80, 9-29-82, 1-29-84, 11-1-84, Formerly 61-41.09, Amended 1-1-87, 3-1-92, 3-1-95, 9-13-01, 7-16-03, 5-13-07, 9-13-09, Formerly 9B-1.009.