Fla. Admin. Code Ann. R. 62-625.400 - Pretreatment Standards: Prohibited Discharges
(1) General prohibitions.
(a) An industrial user shall not introduce
into a WWF or potable reuse system any pollutant which causes pass through or
interference. These general prohibitions and the specific prohibitions in
subsection (2), below, apply to each industrial user introducing pollutants
into a WWF or potable reuse system whether or not the industrial user is
subject to other pretreatment standards, or any national, State, or local
pretreatment requirements.
(b)
Affirmative Defenses. An industrial user shall have an affirmative defense in
any action brought against it alleging a violation of the general prohibitions
established in paragraph (a), above, and the specific prohibitions in
paragraphs (2)(c)-(g), below, where the industrial user can demonstrate that:
1. It did not know or have reason to know
that its discharge, alone or in conjunction with a discharge or discharges from
other sources, would cause pass through or interference; and,
2. Either of the following:
a. A local limit designed to prevent pass
through or interference was developed in accordance with subsection (3), below,
for each pollutant in the industrial user's discharge that caused pass through
or interference, and the industrial user was in compliance with each such local
limit directly prior to and during the pass through or interference;
or
b. If a local limit designed to
prevent pass through or interference has not been developed in accordance with
subsection (3), below, for the pollutants that caused the pass through or
interference, and the industrial user's discharge directly prior to and during
the pass through or interference did not change substantially in nature or
constituents from the industrial user's discharge activity when the WWF or
potable reuse system was regularly in compliance with it's permit requirements
and applicable requirements for
biosolids.
(2) Specific prohibitions. The following
pollutants shall not be introduced into a WWF:
(a) Pollutants which create a fire or
explosion hazard in the WWF;
(b)
Pollutants which will cause corrosive structural damage to the WWF, but in no
case discharges with pH lower than 5.0, unless the WWF is specifically designed
to accommodate such discharges;
(c)
Solid or viscous pollutants in amounts which will cause obstruction to the flow
in the WWF or potable reuse system resulting in interference;
(d) Any pollutant, including oxygen demanding
pollutants, released in a discharge at a flow rate or pollutant concentration
which will cause interference with the WWF or potable reuse system;
(e) Heat in amounts which will inhibit
biological activity in the WWF resulting in interference, but in no case heat
in such quantities that result in the discharge from the treatment plant having
a temperature that exceeds 40º C (104º F) unless the Department, upon
request of the control authority, approves alternate temperature limits in
accordance with Rule 62-302.520, F.A.C.;
(f) Petroleum oil, nonbiodegradable cutting
oil, or products of mineral oil origin in amounts that will cause interference
or pass through;
(g) Pollutants
which result in the presence of toxic gases, vapors, or fumes within the WWF in
a quantity that will cause acute worker health and safety problems;
(h) Any trucked or hauled pollutants, except
at discharge points designated by the control authority; or
(i) Any hazardous waste pharmaceuticals from
healthcare facilities or reverse distributors in accordance with Rule
62-730.181,
F.A.C.
(3) Specific
limits developed by the control authority.
(a) Each public utility required to have a
pretreatment program in accordance with Rule
62-625.500, F.A.C., shall
develop and enforce specific limits to implement the prohibitions listed in
paragraph (1)(a), and subsection (2), above. Each public utility shall continue
to develop these limits as necessary and effectively enforce such
limits.
(b) All other public
utilities shall develop and enforce specific effluent limits which, together
with appropriate changes in the treatment plant or operation, are necessary to
ensure compliance with the WWF's or potable reuse system's permit(s) or
biosolids use or disposal practices.
(c) Specific effluent limits shall not be
developed and enforced without individual notice to persons or groups who have
requested such notice and an opportunity to respond.
(d) The control authority (except where the
Department is acting as the control authority) may develop best management
practices (BMPs) to implement paragraphs (a) and (b), above. Such BMPs shall be
considered local limits and pretreatment standards for the purposes of this
chapter.
(4) Local
limits. Where specific prohibitions or limits on pollutants or pollutant
parameters are developed by a public utility in accordance with subsection (3),
above, such limits shall be deemed pretreatment standards for the purposes of
this chapter.
(5) State enforcement
actions. If, within 30 days after notice of an interference or pass through
violation has been sent by the Department to the control authority, and to
persons or groups who have requested such notice from the Department, the
control authority fails to commence appropriate enforcement action to correct
the violation, the Department shall take appropriate enforcement action in
accordance with Sections
403.121,
403.131 and
403.161,
F.S.
Notes
Rulemaking Authority 403.061(7), (31), 403.0885 FS. Law Implemented 403.0885 FS.
New 11-29-94, Amended 5-10-10, 9-20-21.