Fla. Admin. Code Ann. R. 69A-60.0081 - Notice Required for Structures With Light-frame Truss-type Construction
(1)
Purpose: The purpose of this rule is to require the placement of an identifying
symbol on structures constructed with a light-frame truss component in a manner
sufficient to warn persons conducting fire control and other emergency
operations of the existence of light-frame truss-type construction in the
structure.
(2) Definitions.
(a) "Light-frame truss-type construction"
means a type of construction whose primary structural elements are formed by a
system of repetitive wood or light gauge steel framing members.
(b) "Approved symbol" means a Maltese Cross
measuring 8 inches horizontally and 8 inches vertically, of a bright red
reflective color, designed in accordance with Figure 1.
(3) Any commercial, industrial, or multiunit
residential structure of three units or more, which uses horizontal or vertical
light-frame truss-type construction in any portion shall be marked with an
approved symbol. Townhouses are not multiunit residential structures and
therefore not subject to this rule. Each approved symbol shall include within
the center circle one of the following designations:
(a) Structures with light-frame truss roofs
shall be marked with the letter "R".
(b) Structures with light-frame truss floor
systems shall be marked with the letter "F".
(c) Structures with light-frame truss floor
and roof systems shall be marked with the letters "RF."
(4) The approved symbol shall be placed
within 24 inches to the left of the main entry door and:
(a) Be permanently attached to the face of
the structure on a contrasting background; or
(b) Be mounted on a contrasting base material
which is then permanently attached to the face of the
structure.
(5) The
distance above the grade, walking surface or the finished floor to the bottom
of the symbol shall be not less than 4 feet (48 in.).
(6) The distance above the grade, walking
surface or the finished floor to the top of the symbol shall be not more than 6
feet (72 in.).
(7) In single tenant
structures with multiple main entry doors, such as big box retail stores,
department stores and grocery stores, the authority having jurisdiction is
authorized to require that other main entry doors of the structure be marked
with an approved symbol to carry out the purpose in subsection (1),
above.
(8) In Multiple tenant
structures and covered mall structures with multiple main entry doors, the
authority having jurisdiction is authorized to require that other main entry
doors of the structure be marked with an approved symbol to carry out the
purpose in subsection (1), above.
(9) In multiple tenant structures and covered
malls with multiple main entry doors, the authority having jurisdiction is
authorized to require that other main entry doors be marked with an approved
symbol to carry out the purpose in subsection (1), above. In such structures,
approved symbols shall be marked on one side of the structure only and spaced
not closer than 100 feet or at each end of the structure when such structure is
less than 100 feet in length.
(10)
The owner of each new structure required to comply with this section shall mark
the structure with the approved symbol prior to receiving a certificate of
occupancy.
(11) The owner of each
existing structure required to comply with this section shall mark the
structure with the approved symbol within 90 days of the effective date of this
rule.
(12) Where the owner of the
structure and the authority having jurisdiction disagree as to the use of
light-frame truss-type construction within the structure, the owner shall be
granted not more than 45 days to provide written verification from a licensed
engineer or licensed architect; otherwise, the owner shall comply with the
rule.
Figure 1:
Click here to view image
Light-frame "Roof" only
Click here to view image
Light-frame "Floor" only
Click here to view image
Light-frame "Floor & Roof"
Notes
Rulemaking Authority 633.104(1), 633.202, 633.206, 633.222(2) FS. Law Implemented 633.102, 633.104, 633.206, 633.222 FS.
New 12-13-09.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.