Ga. Comp. R. & Regs. R. 120-3-16-.07 - Adopted Codes and Standards
Except to the extent modified herein, the following NFPA codes and standards are hereby adopted:
Exception No. 1: One listed wall-mounted unvented room heater equipped with an oxygen depletion safety shutoff system shall be permitted to be installed in a bathroom provided that the input rating shall not exceed 6,000 Btu/hr (1760 W/hr) and combustion and ventilation air is provided as specified in 10.1.2.
Exception No. 2: One listed wall-mounted unvented room heater equipped with an oxygen depletion safety shutoff system shall be permitted to be installed in a bedroom provided that the input rating shall not exceed 10,000 Btu/hr (2930 W/hr) and combustion and ventilation air is provided as specified in 10.1.2.
NOTE: Exceptions No. 1 and No. 2 are acceptable installations to the Safety Fire Division. Refer to Rule 120-3-16-.02(12).
Exception: A Georgia dealer in LP-Gas may evacuate a container not owned by such dealer for the purpose of transferring the LP-Gas remaining in the container into a container which is owned by the dealer or the ultimate consumer, provided that the dealer owning the container to be evacuated is notified of the transfer. The Georgia dealer in LP-Gas evacuating the container shall document such notification and shall maintain a record of the notification for a period not less than three years.
No modifications.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
Except to the extent modified herein, the following
Modifications:
"3.3.81 Qualified Agency. A Georgia licensed
"3.3.106 Interruption of Service. Any time when there is a disruption in the flow of gas between the gas supply and the distribution piping, or any portion thereof."
"10.22.1 Prohibited Installations. Unvented room heaters shall not be installed in bathrooms or bedrooms.
Exception No. 1: One listed wall-mounted unvented room heater equipped with an oxygen depletion safety shutoff system shall be permitted to be installed in a bathroom provided that the input rating shall not exceed 6,000 Btu/hr (1760 W/hr) and combustion and ventilation air is provided as specified in 10.1.2.
Exception No. 2: One listed wall-mounted unvented room heater equipped with an oxygen depletion safety shutoff system shall be permitted to be installed in a bedroom provided that the input rating shall not exceed 10,000 Btu/hr (2930 W/hr) and combustion and ventilation air is provided as specified in 10.1.2.
"NOTE: Exceptions No. 1 and No. 2 are acceptable installations to the
Modifications:
"4.4 Qualifications of Personnel. Persons who transfer liquid LP-Gas, who are employed to transport LP-Gas, or whose primary duties fall within the scope of this code shall be trained in accordance with Section 120-3-16-.04 of this
"5.2.1.12 The design, fabrication, and marking provisions for containers and features normally associated with container fabrication, such as container openings, appurtenances required for these openings to make the containers gas tight entities, physical damage protecting devices, and container supports attached to or furnished with the container by the manufacturer shall meet the requirements of this section. All tank distributors or firms who manufacture or sell
"5.23.2 Any appliance originally manufactured for operation with a gaseous fuel other than LP-Gas shall not be used with LP-Gas unless it is converted to use LP-Gas, and is tested for performance with LP-Gas before being placed into use. No
"6.1.4 General Provisions. Bulk storage facilities, cylinder filling facilities, and cylinder exchange staging areas shall have emergency contact information posted in a prominent location accessible to persons who might notice leaks, fires or other unsafe conditions. For bulk storage and cylinder filling facilities the letters shall be at least 2 inches high using approximately a 1/4 inch stroke. At cylinder exchange staging areas the letters shall be 3/4 inches high using approximately a 1/8 inch stroke. 'No smoking' signs shall be conspicuously posted."
"6.8.1.8 Piping, tubing or regulators shall be considered well supported when they are rigidly fastened in their intended position."
"6.24.9_Security and Protection Against Tampering. Vaporizers shall have fencing or protection against tampering in accordance with 6.21.4 and protection against vehicle collision."
"7.2.2.20 No
Exception: A Georgia dealer in LP-Gas may evacuate a container not owned by such dealer for the purpose of transferring the LP-Gas remaining in the container into a container which is owned by the dealer or the
"8.2.3 When cylinders are stored in exchange or storage cages, the name of the lp-gas supplier and the supplier's emergency contact information shall be posted on the front of the cage using letters 3/4 inches high using approximately a 1/8 inch stroke."
"9.1.3 General Provisions."
"9.1.3.1 Drivers shall not be addicted to or under the influence of intoxicants or narcotics, and intoxicating beverages shall not be carried on or consumed in transport vehicles."
"9.1.3.2 Except during transfer operations, the liquid valve(s) of all tanks and cargo tanks trucks shall be closed by means of self-closing shut-off valves."
"9.1.3.3 The transfer of L.P. Gas from vehicle to vehicle at any location which is open to and readily accessible to the public and on any public highway, road, street, or alley is allowed only with approval of the
"9.4.6.3 In addition, the common name of the product or the words 'LIQUEFIED PETROLEUM GAS' shall be marked on the rear and sides of cargo tanks in letters at least 2 inches high using approximately a 1/4 inch stroke, with red letters upon a white background."
"9.4.6.4 The name and telephone number of the owner or operator of any vehicle required to be marked shall be displayed on each side of the vehicle in legible lettering."
Modifications: None