Ga. Comp. R. & Regs. R. 120-3-27-.20 - Electrical Equipment
(1)
The National Electrical Code, NFPA 70 1984, latest adopted version is hereby
adopted as a rule and all future amendments shall be accepted as
adopted.
(2) This document may be
purchased from the National Fire Protection Association, Battermarch Park,
Quincy, MA 02269.
(3) All
electrical wiring and equipment used for amusement rides or for lighting shall
be installed and maintained in accordance with the Rule adopted in (1)
above.
(4) The outlets of
electrical power lines carrying more than 120 volts shall be clearly marked to
show their voltage.
(5) All
electrical transformer substations shall be properly enclosed and proper
warning signs shall be posted.
(6)
Electrical wiring and equipment located outdoors shall be of such quality and
so constructed or protected that exposure to weather will not interfere with
its normal operation.
(7) Elevated
power lines crossing access or other roads within the grounds of a carnival or
amusement park shall be so suspended as to provide a vertical clearance of at
least twelve feet from the road surface or three feet above any vehicle used
within the grounds of a carnival or amusement park. A horizontal clearance of
at least three feet shall be provided on each side of the normal passage space
of vehicles.