Ga. Comp. R. & Regs. R. 120-3-27-.33 - Waste Water Disposal
(1)
Overflow water shall be returned to the filter system or discharged to a waste
system approved by local authorities. Where perimeter overflow water discharges
into a sanitary sewer, a suitable air gap at least 1 1/2 times the discharge
diameter shall be provided to create a gravity drip which has no direct
mechanical connection into the sewer.
(2) When an air gap is impractical, a relief
manhole with a grated cover shall be constructed in the perimeter overflow main
waste line, the clear area of which shall be twice the area of the main waste
piping. It shall be at a level so that the waste flow in the line will rise in
the manhole and overflow at ground level not less than 2 feet (61 cm) below the
level of the perimeter overflow lip.