Ga. Comp. R. & Regs. R. 40-20-1-.11 - Specifications, Tolerances, and Other Technical Requirements for Liquid Measuring Devices
The tolerances for devices used for retail sales of petroleum products regulated shall be as follows:
(a) The maintenance tolerance shall be one
cubic inch plus one cubic inch per indicated gallon.
(b) The acceptance tolerance shall be 1/2 of
the maintenance tolerances.
(c)
Applicable testing and technical requirements shall be in accordance with the
latest Edition of the National Bureau of Standards Handbook 44, except when in
conflict with existing or modified rules and regulations or when rejected by
the same.
(d) Retail devices for
motor fuels shall be condemned for repair when the device exceeds a tolerance
of plus or minus 14.5 cubic inches (8 fluid ounces). Owners or owner's agent of
devices and/or petroleum products dispensed having a tolerance exceeding plus
14.5 cubic inches may request a waiver of condemnation of such device from the
Commissioner of Agriculture, or from a duly appointed agent.
(e) It is recommended that each retail
dispensing device from which diesel fuel is sold shall be equipped with a
nozzle spout having a terminal end with an outside diameter of not less than
23.63 mm (0.930 in).