Haw. Code R. § 11-104.1-12 - Transportation of untreated infectious waste within a generating facility
(a) Untreated infectious waste shall be
placed in containers sufficient to contain the waste completely. Satisfactory
containers include:
(1) Nonsoluble plastic
bags either red in color or clearly labeled with the Universal Biological
Hazard symbol;
(2) Sharps
containers as described in section 11-104.1-11(b)(2); or
(3) Sturdy leakproof containers clearly
marked with the Universal Biological Hazard symbol.
(b) The number of plastic bags and the
thickness of bags shall be sufficient to securely contain the waste completely
from point of generation through treatment and storage.
(c) Bags used for autoclaving shall also be
marked with the Universal Biological Hazard Symbol.
(d) Plastic bags and other containers of
untreated infectious waste shall be tightly closed before transport. The
plastic bags and other containers of waste shall be transported in leakproof
rigid or semi-rigid portable containment systems or carts, clearly marked with
the Universal Biological Hazard symbol.
(e) Untreated infectious waste shall be
transported within a facility in a manner designed to minimize rupturing and
dissemination or aerosolization.
(f) Untreated infectious waste shall not be
transported with noninfectious waste unless all waste in the load is managed as
infectious waste.
(g) Reusable
carts, bins, and other containment systems used to transport waste must be
cleaned after each use and disinfected daily when in use.