Haw. Code R. § 11-113-19 - Quality assurance and quality control
(a)
Laboratories shall have a quality assurance program which encompasses all
aspects of the testing process including but not limited to specimen
acquisition, chain of custody, security and reporting of results, initial and
confirmatory testing, and validation of analytical procedures. Quality
assurance procedures shall be designed, implemented, and reviewed to monitor
the conduct of each step of the process of testing.
(b) Each analytical run of specimens to be
screened shall include:
(1) Specimens
certified to contain no drugs;
(2)
Specimens fortified with known standards; and
(3) Positive controls with the drug or
metabolite at or near the cutoff.
(c) In addition, with each batch of specimens
a sufficient number of standards shall be included to ensure and document the
linearity of the assay method over time in the concentration area of the
cutoff. After acceptable values are obtained for the known standards, those
values will be used to calculate specimen data.
(d) Implementation of procedures to ensure
that carryover does not contaminate the testing of an individual's specimen
shall be documented.
(e) A minimum
of ten per cent of all test specimens shall be quality control specimens.
Laboratory quality control samples, prepared from spiked samples of determined
concentration shall be included in the run and should appear as normal samples
to laboratory analysts.
(f) Each
analytical run of specimens to be confirmed shall include:
(1) Specimens certified to contain no
drugs;
(2) Specimens fortified with
known standards; and
(3) Positive
controls with the drug or metabolite at or near the cutoff.
(g) The linearity and precision of
the method shall be periodically documented.