Haw. Code R. §§ 11-261.1055 - Standards: Sampling connection systems
(a) Each sampling
connection system shall be equipped with a closed-purge, closed-loop, or
closed-vent system. This system shall collect the sample purge for return to
the process or for routing to the appropriate treatment system. Gases displaced
during filling of the sample container are not required to be collected or
captured.
(b) Each closed-purge,
closed-loop, or closed-vent system as required in paragraph (a) of this section
shall meet one of the following requirements:
(1) Return the purged process fluid directly
to the process line;
(2) Collect
and recycle the purged process fluid; or
(3) Be designed and operated to capture and
transport all the purged process fluid to a material management unit that
complies with the applicable requirements of §§ 261.1084 through
264.1086 of this subpart or a control device that complies with the
requirements of § 261.1060 of this subpart.
(c) In-situ sampling systems and sampling
systems without purges are exempt from the requirements of paragraphs (a) and
(b) of this section.