Haw. Code R. § 11-264-1065 - Reporting requirements
(a) A semiannual
report shall be submitted by owners and operators subject to the requirements
of this subchapter to the director by dates specified by the director. The
report shall include the following information:
(1) The EPA identification number, name, and
address of the facility.
(2) For
each month during the semiannual reporting period:
(i) The equipment identification number of
each valve for which a leak was not repaired as required in subsection
11-264-1057(d).
(ii) The equipment
identification number of each pump for which a leak was not repaired as
required in subsection 11-264-1052(c) and paragraph 11-264-1052(d)
(6).
(iii) The equipment
identification number of each compressor for which a leak was not repaired as
required in subsection 11-264-1053(g).
(3) Dates of hazardous waste management unit
shutdowns that occurred within the semiannual reporting period.
(4) For each month during the semiannual
reporting period, dates when the control device installed as required by
section 11-264-1052, 11-264-1053, 11-264-1054, or 11-264-1055 exceeded or
operated outside of the design specifications as defined in subsection
11-264-1064(e) and as indicated by the control device monitoring required by
section 11-264-1060 and was not corrected within twenty-four hours, the
duration and cause of each exceedance, and any corrective measures
taken.
(b) If, during
the semiannual reporting period, leaks from valves, pumps, and compressors are
repaired as required in subsections 11-264-1057(d), 11-264-1052(c) and
paragraph 11-264-1052(d) (6), and subsection 11-264-1053(g), respectively, and
the control device does not exceed or operate outside of the design
specifications as defined in subsection 11-264-1064(e) for more than
twenty-four hours, a report to the director is not required.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.