Haw. Code R. § 11-265-190 - Applicability
(a) Tank systems that are used to store or
treat hazardous waste which contains no free liquids and that are situated
inside a building with an impermeable floor are exempted from the requirements
in section 11-265-193. To demonstrate the absence or presence of free liquids
in the stored/treated waste, the following test must be used: Method 9095
(Paint Filter Liquids Test) as described in "Test Methods for Evaluating Solid
Waste, Physical/Chemical Methods'' (EPA Publication SW-846), as incorporated by
reference in section 11-260-11.
(b)
Tank systems, including sumps, as defined in section 11-260-10, that serve as
part of a secondary containment system to collect or contain releases of
hazardous wastes are exempted from the requirements in subsection
11-265-193(a).
(c) Tanks, sumps,
and other collection devices used in conjunction with drip pads, as defined in
section 11-260-10 and regulated under subchapter W of chapter 11-265, must meet
the requirements of this subchapter.