Haw. Code R. § 11-265-310 - Closure and post-closure care
(a) At final
closure of the landfill or upon closure of any cell, the owner or operator must
cover the landfill or cell with a final cover designed and constructed to:
(1) Provide long-term minimization of
migration of liquids through the closed landfill;
(2) Function with minimum
maintenance;
(3) Promote drainage
and minimize erosion or abrasion of the cover;
(4) Accommodate settling and subsidence so
that the cover's integrity is maintained; and
(5) Have a permeability less than or equal to
the permeability of any bottom liner system or natural subsoils
present.
(b) After final
closure, the owner or operator must comply with all post-closure requirements
contained in sections 11-265-117 through 11-265-120 including maintenance and
monitoring throughout the post-closure care period. The owner or operator must:
(1) Maintain the integrity and effectiveness
of the final cover, including making repairs to the cover as necessary to
correct the effects of settling, subsidence, erosion, or other
events;
(2) Maintain and monitor
the leak detection system in accordance with subparagraph 11-264-301(c)(3)(iv)
and paragraph 11-264-301(c)(4) and subsection 11-265-304(b), and comply with
all other applicable leak detection system requirements of this
chapter;
(3) Maintain and monitor
the ground-water monitoring system and comply with all other applicable
requirements of subchapter F;
(4)
Prevent run-on and run-off from eroding or otherwise damaging the final cover;
and
(5) Protect and maintain
surveyed benchmarks used in complying with section 11-265-309.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.