Haw. Code R. § 11-270-27 - Specific Part B information requirements for air emission controls for tanks, surface impoundments, and containers
(a) Except as
otherwise provided in section 11-264-1, owners and operators of tanks, surface
impoundments, or containers that use air emission controls in accordance with
the requirements of 11-264, subchapter CC shall provide the following
additional information:
(1) Documentation for
each floating roof cover installed on a tank subject to section
11-264-1084(d)(1) or 11-264-1084(d)(2) that includes information prepared by
the owner or operator or provided by the cover manufacturer or vendor
describing the cover design, and certification by the owner or operator that
the cover meets the applicable design specifications as listed in section
11-264-1084(e)(1) or 11-264-1084(f)(1).
(2) Identification of each container area
subject to the requirements of 11-264, subchapter CC and certification by the
owner or operator that the requirements of this subchapter are met.
(3) Documentation for each enclosure used to
control air pollutant emissions from tanks or containers in accordance with the
requirements of section 11-264-1084(d)(5) or 11-264-1086(e) (1) (ii) that
includes records for the most recent set of calculations and measurements
performed by the owner or operator to verify that the enclosure meets the
criteria of a permanent total enclosure as specified in "Procedure T--Criteria
for and Verification of a Permanent or Temporary Total Enclosure" under
40
CFR 52.741, appendix B.
(4) Documentation for each floating membrane
cover installed on a surface impoundment in accordance with the requirements of
section 11-264-1085(c) that includes information prepared by the owner or
operator or provided by the cover manufacturer or vendor describing the cover
design, and certification by the owner or operator that the cover meets the
specifications listed in section 11-264-1085(c)(1).
(5) Documentation for each closed-vent system
and control device installed in accordance with the requirements of section
11-264-1087 that includes design and performance information as specified in
sections 11-270-24(c) and (d).
(6)
An emission monitoring plan for both Method 21 in 40 CFR part 60, appendix A
and control device monitoring methods. This plan shall include the following
information: monitoring point(s), monitoring methods for control devices,
monitoring frequency, procedures for documenting exceedances, and procedures
for mitigating noncompliances.
(7)
When an owner or operator of a facility subject to 11-265, subchapter CC cannot
comply with 11-264, subchapter CC by the date of permit issuance, the schedule
of implementation required under section 11-265-1082.