Haw. Code R. § 16-72-53 - Sanitation practices
Required practices shall include:
(1) A fresh, disposable paper or a fresh
sheet shall be used on the examining table for each patient;
(2) Hands shall be washed with soap and water
before handling a needle and between treatment of different patients;
(3) A piercing needle shall be previously
unused and sterilized;
(4) A
piercing needle shall not be used more than once per treatment and shall be
disposed of immediately after use in the manner prescribed in paragraph (8)
below;
(5) Skin, in the area of any
acupuncture procedure, shall be thoroughly swabbed with germicidal solution
before using any needles;
(6) If
the sterility of an unused needle or instrument has been compromised, it shall
be sterilized at a minimum temperature of 250?F (or 121?C) for not less than
thirty minutes at fifteen pounds of pressure per square inch before
usage;
(7) Prior to its usage on a
patient, a reusable instrument or a non-piercing acupuncture needle shall be
sterilized at a minimum temperature of 250?F (or 121?C) for not less than
thirty minutes at fifteen pounds of pressure per square inch;
(8) All used needles for disposal shall be
placed in a hazardous waste container that meets standards set by the
department of health. All handling of the container, including but not limited
to treating, transporting, and disposing of the container, shall conform with
the laws and rules of the department of health; and
(9) Other reasonable sanitation procedures
and practices recommended by governmental agencies or manufacturers shall be
followed to protect the health and safety of patients and the public.