Haw. Code R. § 6-77-180 - Transmission lines: permanent field repair of welds
Each weld that is unacceptable under section 6-77-80(c) must be repaired as follows:
(1) If it is
feasible to take the segment of transmission line out of service, the weld must
be repaired in accordance with the applicable requirements of section
6-77-82.
(2) A weld may be repaired
in accordance with section 6-77-82 while the segment of transmission line is in
service if:
(A) The weld is not
leaking;
(B) The pressure in the
segment is reduced so that it does not produce a stress that is more than
twenty percent of the SMYS of the pipe; and
(C) Grinding of the defective area can be
limited so that at least 1/8-inch thickness in the pipe weld remains;
(3) A defective weld which cannot
be repaired in accordance with paragraph (1) or (2) must be repaired by
installing a full encirclement welded split sleeve of appropriate
design.