Haw. Code R. § 6-77-47 - Components fabricated by welding
(a) Except for
branch connections and assemblies of standard pipe and fittings jointed by
circumferential welds, the design pressure of each component fabricated by
welding, whose strength cannot be determined, must be established in accordance
with paragraph UG-101 of section VIII of the ASME Boiler and Pressure Vessel
Code.
(b) Each prefabricated unit
that uses plate and longitudinal seams must be designated, constructed, and
tested in accordance with the ASME Boiler and Pressure Vessel Code, except for
the following:
(1) Regularly manufactured
butt-welding fittings;
(2) Pipe
that has been produced and tested under a specification listed in Appendix
B;
(3) Partial assemblies such as
split rings or collars;
(4)
Prefabricated units that the manufacturer certifies have been tested to at
least twice the maximum pressure to which they will be subjected under the
anticipated operating conditions.
(c) Orange-peel bull plugs and orange-peel
swages may not be used on pipelines that are to operate at a hoop stress of
twenty percent or more of the SMYS of the pipe.
(d) Except for flat closures designed in
accordance with section VIII of the SME Boiler and Pressure Code, flat closures
and fish tails may not be used on pipe that either operates at 100 p.s.i.g., or
more, or is more than three inches nominal diameter.