Haw. Code R. §§ 11-265.1063 - Test methods and procedures
(a) Each owner or
operator subject to the provisions of this subpart shall comply with the test
methods and procedures requirements provided in this section.
(b) Leak detection monitoring, as required in
§§265.1052 through 265.1062, shall comply with the following
requirements:
(1) Monitoring shall comply with
Reference Method 21 in 40 CFR part 60.
(2) The detection instrument shall meet the
performance criteria of Reference Method 21.
(3) The instrument shall be calibrated before
use on each day of its use by the procedures specified in Reference Method
21.
(4) Calibration gases shall be:
(i) Zero air (less than 10 ppm of hydrocarbon
in air).
(ii) A mixture of methane
or n-hexane and air at a concentration of approximately, but less than, 10,000
ppm methane or n-hexane.
(5) The instrument probe shall be traversed
around all potential leak interfaces as close to the interface as-possible as
described in Reference Method 21.
(c) When equipment is tested for compliance
with no detectable emissions, as required in §§ 265.1052(e),
265.1053(i), 265.1054, and 265.1057(f), the test shall comply with the
following-requirements:
(1) The requirements
of paragraphs (b)(1) through (4) of this section shall apply.
(2) The background level shall be determined,
as set forth in Reference Method 21.
(3) The instrument probe shall be traversed
around all potential leak inter-faces as close to the interface as-possible as
described in Reference Method 21.
(4) The arithmetic difference between the
maximum concentration indicated by the instrument and the background level is
compared with 500 ppm for determining compliance.
(d) In accordance with the waste analysis
plan required by §265.13(b), an owner or operator of a facility must
determine, for each piece of equipment, whether the equipment contains or
contacts a hazardous waste with organic concentration that equals or exceeds 10
percent by weight using the following:
(1)
Methods described in ASTM Methods D 2267-88, E 169-87, E 168-88, E 260-85
(incorporated by reference under §260.11);
(2) Method 9060A (incorporated by reference
under § 260.11 of this chapter) of "Test Methods for Evaluating Solid
Waste," EPA Publication SW-846 or analyzed for its individual organic
constituents; or
(3) Application of
the knowledge of the nature of the hazardous waste stream or the process by
which it was produced. Documentation of a waste determination by knowledge is
required. Examples of documentation that shall be used to support a
determination under this provision include production process information
documenting that no organic compounds are used, information that the waste is
generated by a process that is identical to a process at the same or another
facility that has previously been demonstrated by direct measurement to have a
total organic content less than 10 percent, or prior speciation analysis
results on the same waste stream where it can also be documented that no
process changes have occurred since that analysis that could affect the waste
total organic concentration.
(e) If an owner or operator determines that a
piece of equipment contains or contacts a hazardous waste with organic
concentrations at least 10 percent by weight, the determination can be revised
only after following the procedures in paragraph (d)(1) or (d)(2) of this
section.
(f) When an owner or
operator and the director do not agree on whether a piece of equipment contains
or contacts a hazardous waste with organic concentrations at least 10 percent
by weight, the procedures in paragraph (d)(1) or (d)(2) of this section can be
used to resolve the dispute.
(g)
Samples used in determining the percent organic content shall be representative
of the highest total organic content hazardous waste that is expected to be
contained in or contact the equipment.
(h) To determine if pumps or valves are in
light liquid service, the vapor pressures of constituents may be obtained from
standard reference texts or may be determined by ASTM-D-2879-86 (incorporated
by reference under §260.11).
(i) Performance tests to determine if a
control device achieves 95 weight percent organic emission reduction shall
comply with the procedures of § 265.1034 (c)(1) through (c)(4).
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.