Haw. Code R. tit. 3, Building Code Council, State Building Code, AMENDMENTS TO THE 2018 ICC INTERNATIONAL EXISTING BUILDING CODE (IEBC), 4 - Bracing of Post and Pier Foundations

Section 303.3.3 is added to read as follows:

"[BS]303.3.3 Pre-engineered bracing of post and pier foundations.

For conventional light-framed single family residences two stories or less above grade, seismic bracing retrofits of elevated wood post and pier foundation systems shall be permitted to be pre-engineered designs for braces or shear walls constructed in accordance with FEMA Hazard Mitigation Grant Program DR-1664-HI drawings, Structural Seismic Retrofits for Hawaii Single Family Residences with Post and Pier Foundations, May 2009."

Notes

Haw. Code R. tit. 3, Building Code Council, State Building Code, AMENDMENTS TO THE 2018 ICC INTERNATIONAL EXISTING BUILDING CODE (IEBC), 4
[Eff 11/17/2020]

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.