Haw. Code R. tit. 3, Building Code Council, State Elevator Code, subtit. 8, pt. 11, ch. 229, exh. C - INSPECTION AND TEST INTERVALS (IN MONTHS)
January 1, 2017
|
Equipment Type |
Permit Renewal |
Category 3 |
Category 5 |
|
Electrical Elevators |
12 |
N/A |
60 |
|
Hydraulic Elevators |
12 |
36 |
N/A |
|
Escalators and Moving Walks[1] |
12 |
36 |
N/A |
|
Dumbwaiters |
12 |
36 |
60 |
|
Material Lifts |
12 |
36 |
60 |
|
Platform Lifts and Stairway Chairlifts |
12 |
N/A |
N/A |
|
Inclined Elevators |
12 |
36 |
60 |
|
Screw-Column Elevators |
12 |
36 |
60 |
|
Roof-top Elevators |
12 |
36 |
60 |
|
Limited-use/Limited-Application Elevators |
3 |
36 |
60 |
|
Construction Cars |
3 |
36 |
60 |
|
Personnel Hoists[2] |
3 |
N/A |
N/A |
|
Amusement Rides |
6 |
N/A |
N/A |
1 Internal inspections of escalators and moving walks shall be performed at intervals of 36 months.
2 Personnel hoists shall be load tested at intervals of 3 months.
Where an equipment is listed under both Category 3 of 36 months and Category 5 of 60 months, the appropriate testing interval is dependent on whether the lifting mechanism is rope or hydraulic or a combination of rope and hydraulic.