Ill. Admin. Code tit. 32, pt. 315, tbl. D - Limiting Apertures for Hazards Evaluation and AEL Determination
|
Spectral Region (µm) |
Duration (s) |
Aperture Diameter (mm) |
||||||
|
Eye |
Skin |
|||||||
|
0.180 to 0.400 |
10-9 to 0.25 |
1.0 |
3.5 |
|||||
|
0.25 to 3 x 104 |
3.5 |
3.5 |
||||||
|
0.400 to 1.400 |
10-9 to 3 x 104 |
7.0 |
3.5 |
|||||
|
1.400 to 102 |
10-9 to 0.3 |
1.0 |
3.5 |
|||||
|
0.3 to 10 |
1.5 t3/8 |
3.5 |
||||||
|
10 to 3 x 104 |
3.5 |
3.5 |
||||||
|
102 to 103 |
10-9 to 3 x 104 |
11.0 |
11.0 |
|||||
|