Ill. Admin. Code tit. 32, § 351.350 - Leak Testing of Sealed Sources
a)
Testing and Recordkeeping Requirements. Each licensee who uses a sealed source
shall have the source tested for leakage as described in subsection (c). The
licensee shall keep a record of leak test results under 32 Ill. Adm. Code
340.1135.
b) Method of Testing. The wipe of a sealed
source shall be performed using a leak test kit or method approved by the
Agency, the U.S. Nuclear Regulatory Commission, or an Agreement State. The wipe
sample shall be taken from the nearest accessible point to the sealed source
where contamination might accumulate. The wipe sample shall be analyzed for
radioactive contamination. The analysis shall be capable of detecting the
presence of 185 Bq (0.005 microcuries) of radioactive material on the test
sample and shall be performed by a person approved by the Agency, the U.S.
Nuclear Regulatory Commission, or an Agreement State to perform the
analysis.
c) Test Frequency
1) Each sealed source, except an energy
compensation source (ECS), shall be tested at intervals not to exceed 6 months.
In the absence of a certificate from a transferor that a test has been made
within the 6 months before the transfer, the sealed source may not be used
until tested.
2) Each ECS that is
not exempt from testing pursuant to subsection (e) shall be tested at intervals
not to exceed 3 years. In the absence of a certificate from a transferor that a
test has been made within the 3 years before the transfer, the ECS may not be
used until tested.
d)
Removal of Leaking Source from Service
1) If
the test conducted pursuant to subsections (a) and (b) reveals the presence of
185 Bq (0.005 microcuries) or more of removable radioactive material, the
licensee shall remove the sealed source from service immediately and have it
decontaminated, repaired, or disposed of by an Agency, U.S. Nuclear Regulatory
Commission, or Agreement State licensee that is authorized to perform these
functions. The licensee shall check the equipment associated with the leaking
source for radioactive contamination and, if contaminated, have it
decontaminated or disposed of by an Agency, U.S. Nuclear Regulatory Commission,
or Agreement State licensee that is authorized to perform these
functions.
2) Reports of test
results for leaking or contaminated sealed sources shall be made pursuant to 32
Ill. Adm. Code 340.1260.
e) Exemptions from Testing Requirements. The
following sealed sources are exempt from the periodic leak test requirements
set out in subsections (a) through (d):
1)
Hydrogen-3 (tritium) sources;
2)
Sources containing licensed material with a half-life of 30 days or
less;
3) Sealed sources containing
licensed material in gaseous form;
4) Sources of beta- or gamma-emitting
radioactive material with an activity of 3.7 MBq (100 microcuries) or less;
and
5) Sources of alpha- or
neutron-emitting radioactive material with an activity of 0.37 MBq (10
microcuries) or less.