Ill. Admin. Code tit. 32, § 390.50 - Radiation Monitoring
a)
Portable radiation monitoring equipment shall be properly maintained and
available at the accelerator facility. An appropriate radiation monitor shall
be used for all accelerator target rooms and other high radiation areas. This
monitor shall be one or more of the following:
1) An area monitor with an easily observable
indicator located near the entrance that warns of radiation levels above a
predetermined limit;
2) A personal
radiation monitor of the "chirpie" type worn while in the room;
3) A portable survey instrument carried into
the room; or
4) A monitor approved
by the Agency.
b) No
registrant shall permit any individual to enter a restricted area unless the
individual wears both:
1) An individual
monitoring device, assigned to and worn by only one individual, that is
provided and evaluated by a qualified dosimetry processor as described in 32
Ill. Adm. Code
340.510(d);
and
2) A direct reading pocket
ionization chamber or an electronic dosimeter capable of measuring doses from
zero to at least 51.6 microC/kg (200 mR).