Temperature and pH affect the numeric total ammonia nitrogen water quality standard. Both stream temperature and pH can be expected to be different than discharge temperature and pH; therefore, the calculation of the water quality standard and permit limits will be based on conditions expected to exist downstream of the discharge.
a) Where receiving stream specific data is
available, that data shall be the basis for the selection of temperature and pH
values to be used in calculating total ammonia nitrogen standards upon which an
NPDES permit limit will be based. A data collection station downstream of the
discharge at or beyond the point where complete mixing has occurred is
preferred. When receiving stream specific data is not available, data from the
closest representative Agency water quality monitoring station during the most
recent five years will be used in this conversion formula. The temperature will
be set at the 75th percentile (75 percent of the
values are less than) from data collected during the period for which the water
quality standard is being calculated. The pH value will be set at the
75th percentile (75 percent of the values are less
than) from data collected during the period for which the water quality
standard is being calculated. If the 75th percentile
pH value results in a permit limit for chronic exposure conditions (monthly
average ammonia permit limit) less than 1.5 mg/L for the summer period or 4.0
mg/L for the winter period, the values will be recalculated based on a
50th percentile pH value (half the values are less
than). The permit limit will then be set at the value derived with a
50th percentile pH as long as that value does not
exceed 1.5 mg/L for the summer period and 4.0 mg/L for the winter period. If a
50th percentile pH value would allow a higher summer
limit than 1.5 mg/L, the limit will be set at 1.5 mg/L. If a
50th percentile pH would allow a higher winter limit
than 4.0 mg/L, the winter limit would be set at 4.0 mg/L. Limits based in the
subchronic ammonia standard will be 2.5 times the chronic limit established by
the above procedure.
1) Unless a different
configuration is found by the Agency to be appropriate two permit limits for
summer will be calculated separately using pH and temperature data from the
following periods:
A) March, April, May,
September and October.
B) June,
July and August.
2)
Unless a different configuration is found by the Agency to be appropriate,
permit limits for winter will be calculated using pH and temperature data from
November, December, January and February.
b) When sufficient stream specific
information is available with simultaneous measurements of total ammonia, pH,
and temperature, a relationship reflecting the dynamic interaction between pH,
temperature and ammonia equilibrium may be developed instead of the approach
presented in subsection (a).
c) The
above calculations allow acute, chronic and subchronic ammonia nitrogen water
quality standards to be applied as daily maximum, monthly average and weekly
average permit limits, respectively.