Ill. Admin. Code tit. 35, § 724.955 - Standards: Sampling Connecting Systems
a) Each sampling connection system must be equipped with a closed-purge, closed-loop, or closed-vent system. This system must collect the sample purge for return to the process or for routing to the appropriate treatment system. Gases displaced during filling of the sample container are not required to be collected or captured.
b) Each closed-purge, closed-loop, or closed-vent system, as required in subsection (a), must meet one of the following requirements:
1) It must return the purged process fluid directly to the process line;
2) It must collect and recycle the purged process fluid; or
c) In-situ sampling systems and sampling systems without purges are exempt from the requirements of subsections (a) and (b).
Notes
Amended at 27 Ill. Reg. 3725, effective February 14, 2003