Ill. Admin. Code tit. 41, § 175.810 - Out of Service
a) USTs
may be put into an out of service status provided they meet the performance
standards for new UST systems or the upgrading requirements specified in 41
Ill. Adm. Code 174, 175 and 176 and 40 CFR 280, except that spill and overfill
prevention equipment requirements do not have to be met. The USTs may continue
in an out of service status for a period of 5 years from the date of last use
provided they meet the following requirements:
1) The tank and product lines shall be
emptied immediately upon placing the UST in an out of service status. The UST
is empty when all materials have been removed using commonly employed practices
so that no more than 2.5 centimeters (one inch) of residue, or 0.3% by weight
of the total capacity of the UST system, remain in the system.
2) Pursuant to Sections
175.500 and
175.510, all corrosion
protection shall be maintained and operational for all tanks and lines, and
tested as required, to include flex/pipe connectors. This will include any
monthly logs that need to be maintained.
3) OSFM must receive a written request,
within 30 days after the date the tank was last used, requesting an out of
service status. The request shall be submitted on a Notification for
Underground Storage Tanks on OSFM forms (available at
https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html).
4) Vent lines shall be left open and
functioning.
5) Financial
responsibility shall be maintained until such time as the UST is removed or
abandoned-in-place in accordance with OSFM rules (see 41 Ill. Adm. Code
176.245).
6) Within 7 days, the owner/operator shall
cap and secure all product lines and secure all pumps, manways and ancillary
equipment.
7) Subject to all other
applicable OSFM requirements, a UST may be put back in operation any time
during the first 12 months, without meeting the requirements of subsection (d),
subject to the requirement that OSFM be notified in writing on the Notification
for Underground Storage Tanks form at least 10 days prior to operation. The
form is available at the website cited in subsection (a)(3).
b) Failure to maintain impressed
current system corrosion protection on any tank or piping systems at any point
during the remaining 4-year out of service period referenced in subsection (d)
shall require the removal of the USTs. When testing of anodes has been delayed
past the regular 3-year testing interval, any anode system that fails testing
shall require removal of the affected tanks or piping.
c) Failure to empty tanks in an out of
service status shall require the owner to remove all contents to less than an
inch before proceeding with bringing the tanks back into service.
d) Systems that have been out of use for over
one year but less than 5 years may be put back in service provided that the
facility meets all the applicable requirements in Parts 172, 174, 175, 176 and
177 and the following additional requirements are met:
1) Tanks and lines shall be precision tested
and proven sufficient.
2) Tank and
line release detection is tested and proven operational.
3) Cathodic protection is tested and proven
sufficient.
4) A site assessment is
conducted prior to bringing the UST back into service.
5) All tests referenced in subsections (d)(1)
through (d)(3) must be performed not more than 90 days and not less than 30
days before placing the tank back in service and submitted to OSFM at least 10
days prior to reopening so that a certification audit can be
performed.
6) Prior to a tank being
put back in service, all requirements for return to service must be met, and
all testing and inspections passed, and a Notification for Underground Storage
Tanks Form placing the tanks "Currently in Use" must be submitted. The form is
available at the OSFM website cited in subsection (a)(3) above.
e) Single-wall USTs over 30 years
old that have been in an out of service status more than one year shall be
removed rather than placed back into service.
f) If a UST is not placed back into service
within 5 years from the date of last use, the tank system shall be removed
within 60 days after the conclusion of the 5-year period.
g) USTs with double-walled tanks and piping
shall not be subject to the 5-year limit during the period that is 30 years
after the date of installation or while the tank manufacturer's warranty is in
place, whichever is less, if all of the following requirements are met:
1) Corrosion protection has been and
continues to be maintained;
2) Any
UST components found to be defective are replaced in the 45 days prior to any
return to service; and
3) All
requirements for return to service under subsection (d) and this Section are
met.
h) For purposes of
this Section, "back in service" means that all regulatory requirements for a
return to service have been met, and that the facility has begun regular
dispensing operations typical for the location and is compliant with all leak
detection, corrosion protection, and operator training requirements.