Ill. Admin. Code tit. 77, § 250.1090 - Sterilization and Processing of Supplies
a) All sterilization and processing of all
sterile supplies and equipment shall be under competent, qualified supervision.
1) The director or person responsible for
central services shall be responsible to the chief executive officer either
directly or through a designated department head. The director of the central
sterile supply shall be qualified for the position by education, training, and
experience and shall be a member of the Infection Control Committee. (See
Section 250.1100(a).)
2) The number of supervisory and support
personnel shall be related to the scope of the services provided. New employees
shall receive initial orientation and on-the-job training, and all employees
shall participate in a continuing in-service education program, which shall be
documented.
3) Educational efforts,
though directed primarily at sterile-supply processing and handling techniques,
shall also include management concepts, safety, personal hygiene, health
requirements, and work attire.
b) There shall be written policies and
procedures for the decontamination and sterilization activities performed in
central services and elsewhere in the hospital. The hospital shall comply with
the Centers for Disease Control and Prevention Guidelines for Disinfection and
Sterilization in Healthcare Facilities. These policies and procedures shall
include, but are not limited to, the following:
1) The receiving, decontaminating, cleaning,
preparing, disinfecting and sterilizing of reusable items.
2) The assembly, wrapping, storage,
distribution, and quality control of sterile equipment and medical supplies.
Load control numbers shall be used to designate the hospital sterilization
equipment used for each item, including the sterilization date and
cycle.
3) The use of sterilization
process monitors, including temperature and pressure recordings, and the use
and frequency of appropriate chemical indicator and bacteriological spore tests
for all sterilizers.
4) Designation
of the shelf life for each hospital-wrapped and -sterilized medical item and,
to the maximum degree possible, for each commercially prepared item.
A) Designation of a shelf life may be a
specific expiration date, i.e., 30 days, six months, etc., based on
manufacturer's recommendation, a nationally recognized authority, or other
standard approved by the facility's Infection Control Committee.
B) Designation of shelf life may be event
related if policies and procedures, approved by the Infection Control
Committee, address at least the following:
i)
requirements for wrapping, storage and rotation of sterile supplies;
ii) definition of an event that may cause a
sterile item to be or be suspected of being compromised, such as the package
being wet or torn, or the seal being broken or tampered with;
iii) clear direction that the final
inspection of the package and the ultimate decision to use the contents of the
package rest with the clinician; and
iv) orientation, in-service and other
follow-up training to assure that all necessary staff understand and implement
the policies and procedures.
C) A facility may choose to use both a
specific expiration date and event-related shelf life designation specific for
certain wrappings, areas of the hospital, etc., as long as the policies and
procedures, as approved by the Infection Control Committee, and the training of
staff define this practice.
5) Acquisition of supplies after normal
working hours or any time the central service or sterile supply unit is
considered "closed" or unstaffed.
6) Preventive maintenance of all central
supply service equipment, including performance verification records and
reports.
7) The recall and disposal
or reprocessing of expired or inadequately sterilized supplies.
8) The emergency collection and disposition
of supplies when special warnings have been issued by the manufacturer. The
attending physician shall be notified when patient exposure is known.
9) Specific aeration requirements for each
category of gas-sterilized items to eliminate the hazard of toxic
residues.
10) The cleaning and
sanitizing of work surfaces, floors, utensils, and equipment used in central
service functions.
c)
Space shall be provided for the efficient operation of all central service
functions. Functional design and work flow patterns shall provide for the
separation of soiled and contaminated supplies from those that are clean and
sterile. Equipment of adequate design, size, and type shall be provided for the
effective decontaminating, disinfecting, cleaning, packaging, sterilizing,
storing, and distributing of medical instruments, supplies, and equipment used
in patient care.
d) Equipment and
procedures
1) The facilities, equipment, and
procedures for clean-up, preparation, and sterilization shall be adequate to
allow proper cleaning, processing, and sterilizing of patient care supplies and
equipment.
2) When clean-up,
preparation, and sterilization functions are carried out in the same room or
unit (as in a central sterilizing department) the physical facilities and
equipment and the policies and procedures for their use shall be such as to
effectively separate soiled or contaminated supplies and equipment from the
clean or sterilized supplies and equipment.
3) Sterilization equipment shall be
maintained in good repair and under the provisions of a preventive maintenance
program of the Engineering and Maintenance Services. (Refer to Subpart
P.)
4) All pressure steam
autoclaves shall have recording thermometers, and the sterilization performance
shall be otherwise checked.
e) Sterilization of instruments and utensils
1) All surgical instruments not adversely
affected by high temperature shall be sterilized by pressure steam
sterilization.
2) The steam method
of sterilization is the preferred method for sterilizing medical and surgical
instruments that are not damaged by heat, steam, pressure, or moisture.
Low-temperature sterilization technologies (e.g., Ethylene Oxide (EtO),
hydrogen peroxide gas plasma) may be used for reprocessing patient care
equipment that is heat or moisture sensitive. In addition, a peracetic acid
immersion system of sterilization may be used to sterilize heat-sensitive
immersible medical and surgical items, and dry-heat sterilization may be used
to sterilize items (e.g., powders, oils) that can sustain high temperatures.
Operating parameters and guidelines for each method or system of sterilization
shall be followed for whichever method is used.
3) All instruments shall be thoroughly
cleaned before sterilization.
4)
Boiling is not an approved method of sterilization.
f) Water sterilization
1) When non-commercial sterile water is
utilized, water sterilization equipment shall be maintained and operated in a
manner that will protect the sterilized water from contamination.
2) An acceptable method for checking the
sterility of the water shall be utilized. Water may be sterilized either in
approved water sterilizers or autoclaved in approved flasks.
g) Sterilization and storage of
supplies and equipment
1) Supplies and
equipment shall be properly wrapped and labeled before sterilization.
2) The effectiveness of hospital
sterilization shall be checked. Mechanical, chemical, and biologic monitors
shall be used to ensure the effectiveness of the sterilization process.
Indicators shall be used to show that the items have been sterilized. A
procedure shall be established for the recall of expired or inadequately
sterilized goods for both in-house and commercially sterilized supplies and
equipment. Refer to Section
250.1100(a).
3) Supplies and equipment commercially
prepared so as to retain sterility indefinitely are acceptable. The hospital
shall satisfy itself of the sterility of such materials.
4) Sterile equipment and supplies shall be
stored properly in clean cabinets, cupboards or other suitable enclosed spaces.
An orderly system of rotation of supplies is recommended so that supplies
stored first will be used first.
h) Transmissible spongiform encephalopathies
(TSEs)
1) Records shall be maintained for at
least 20 years regarding quarantine, disposal, decontamination, and
sterilization of surgical instruments used for patients with a confirmed or
suspected TSE.
2) For the purposes
of this Section, TSEs are a group of rapidly progressive, invariably fatal
neurodegenerative diseases that affect both humans and animals. TSEs in humans
include Creutzfeldt-Jakob disease (CJD), kuru, Gerstmann-Straussler-Scheinker
syndrome (GSS), fatal familial insomnia (FFI), and variant CJD
(vCJD).
Notes
Amended at 34 Ill. Reg. 19031, effective November 17, 2010
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.