Ill. Admin. Code tit. 77, § 785.415 - Equipment and Utensils
a) General
Construction, Repair, and Installation
1) The
equipment and utensils used for processing milk and manufacture of dairy
products shall be constructed to be easily demountable where necessary for
cleaning and sanitizing. The product contact surfaces of all utensils and
equipment such as holding tanks, pasteurizers, coolers, vats, agitators, pumps,
sanitary piping, and fittings or any specialized equipment shall be constructed
of stainless steel, or other equally corrosion-resistant material. Nonmetallic
parts other than glass having product contact surfaces shall meet 3-A Sanitary
Standards for Plastic or Rubber and Rubberlike Materials.
2) All equipment and piping shall be designed
and installed so as to be easily accessible for cleaning, and shall be kept in
good repair, free from cracks and corroded surfaces. New or rearranged
equipment shall be set away from any wall or spaced in such a manner as to
facilitate cleaning and to maintain good housekeeping. All parts or interior
surfaces of equipment, pipes (except certain piping cleaned in place) or
fittings, including valves and connections, shall be accessible for inspection.
Milk and dairy product pumps shall be of a sanitary type and easily dismantled
for cleaning or shall be of approved construction to allow effective cleaning
in place in accordance with 3-A Sanitary Standards.
3) All CIP systems shall comply with the 3-A
Sanitary Practices for permanently Installed Sanitary Product, Pipelines, and
Cleaning Systems.
b)
Weigh Cans and Receiving Tanks: Weigh cans and receiving tanks shall meet the
3-A Sanitary Standards and shall be easily accessible for cleaning both inside
and outside and shall be elevated above the floor and protected sufficiently
with covers and baffles to prevent contamination from splash, condensate, and
drippage. When necessary to provide easy access for cleaning of floors and
adjacent wall areas, the receiving tank shall be equipped with wheels or
casters to allow easy removal.
c)
Can Washers: Can washers shall have sufficient capacity and ability to
discharge a clean, dry can and cover and shall be kept properly timed in
accordance with the instructions of the manufacturer. The water and steam lines
supplying the washer shall maintain a uniform pressure and be equipped with
pressure regulating valves.
d)
Product Storage Tanks or Vats: Storage tanks or vats shall be fully enclosed or
tightly covered and well insulated. The entire interior surface, agitator and
all appurtenances shall be accessible for thorough cleaning and inspection. Any
opening at the top of the tank or vat including the entrance of the shaft shall
be protected against the entrance of dust, moisture, insects, oil, or grease.
The sight glasses, if used, shall be sound, clear, and in good repair. Vats
which have hanged covers shall be so designed that moisture or dust on the
surface cannot enter the vat when the covers are raised. If the storage tanks
or vats are equipped with air agitation, the system shall be of an approved
type and properly installed in accordance with the 3-A Accepted Practices for
Supplying air Under Pressure. Storage tanks or vats intended to hold product
for longer than approximately 8 hours shall be equipped with refrigeration
and/or have insulation. All new storage tanks or vats shall meet the
appropriate 3-A Sanitary Standards and shall be equipped with thermometers in
good operating order.
e)
Separators: All product contact surfaces of separators shall be free from rust
and pits and insofar as practicable shall be a stainless steel or other equally
noncorrosive metals.
f) Coil or
Dome-type Batch Pasteurizers: Coil or dome-type batch pasteurizers shall be
stainless steel lined and if the coil is not stainless steel or other equally
noncorrosive metal it shall be tinned over the entire surface. Sanitary seal
assemblies at the shaft ends of coil vats shall be of the removable type,
except that existing equipment not provided with this type gland will be
acceptable if the packing glands are maintained and operated without
contaminating the milk or milk products. New or replacement units shall be
provided with removable packing glands. Dome-type pasteurizer agitators shall
be stainless steel except that any nonmetallic parts shall meet 3-A Sanitary
Standards for Plastic or Rubber and Rubberlike Materials, as applicable. Each
pasteurizer used for heating product at 165° F. or lower for 30 minutes or
less shall be equipped with space heating equipment and the necessary
thermometers to insure a temperature at least 5° F. above that required for
pasteurization of the product. There shall be a means of controlling the
temperature of the heating medium. Batch pasteurizers shall have temperature
indicating and recording devices.
g) High-temperature, Short-time (HTST)
Pasteurizers: When pasteurization is intended or required, an approved timing
pump or device recorder-controller, automatic flow diversion valve and holding
tube or its equivalent, if not a part of the existing equipment, shall be
installed on all HTST equipment used for pasteurization, to assure complete
pasteurization ( 21 CFR 133 and 135). The entire facility shall meet the 3-A
Accepted Practices for the Sanitary Construction, Installation, Testing, and
Operation of High-Temperature, Short-Time Pasteurizers. After the HTST unit has
been tested according to the 3-A Accepted Practices, the timing pump or device
and the recorder controller shall be sealed at the correct setting to assure
pasteurization. Sealing of the HTST unit shall be performed by the Department.
The H.T.S.T. pasteurizer shall be tested initially and annually by the
Department, also whenever any alteration or replacement is made which affects
the proper operation of the instrument or device. When direct steam
pasteurizers are used, the steam, prior to entering the product, shall be
conducted through a steam strainer and a steam purifier equipped with a steam
trap and only steam meeting the requirements for culinary steam shall be used
(See Section 785.410(d)).
h) Thermometers and Recorders
1) Indicating Thermometers:
A) Long-stem indicating thermometers which
are accurate within 0.5 ° F., plus or minus, for the applicable temperature
range, shall be provided for checking the temperature of pasteurization and
cooling of products in vats and checking the accuracy of recording
thermometers.
B) Short-stem
indicating thermometers, which are accurate within 0.5° F., plus or minus,
for the applicable temperature range, shall be installed in the proper
stationary position in all HTST, and dome-type pasteurizers. Storage tanks
where temperature readings are required shall have thermometers which are
accurate within 2.0 ° F., plus or minus.
C) Air-space indicating thermometers, where
applicable, which are accurate within 1.0 ° F., plus or minus, for the
proper temperature range shall also be installed above the surface of the
products pasteurized in vats, to make certain that the temperature of the foam
and/or air above the products pasteurized also received the required minimum
temperature treatment.
2) Recording Thermometers:
A) HTST recording thermometers that are
accurate within 1° F., plus or minus, for the applicable temperature range
shall be used on each heat treating, pasteurizing, or sterilizing unit to
record the heating process.
B)
Additional use of recording thermometers accurate within 2° F., plus or
minus, shall be required where a record of temperature or time of cooling and
holding is of significant importance.
i) Surface Coolers: Surface coolers shall be
equipped with hinged or removable covers, for the protection of the product.
The edges of the fins shall be so designed as to divert condensate on
nonproduct contact surfaces away from product contact surfaces. All gaskets or
swivel connections shall be leak proof.
j) Plate-type Heat Exchangers: Plate-type
heat exchangers shall meet the 3-A Sanitary Standards for Construction and
Installation. All gaskets shall be tight and kept in good operating order.
Plates shall be opened for inspection by the operator at sufficiently frequent
intervals to determine if the equipment is clean and in good repair (e.g. free
of dents, holes, broken gaskets and cracks). A cleaning regimen shall be posted
to insure cleaning procedures between inspection periods.
k) Internal Return Tubular Heat Exchangers:
Internal return tubular heat exchangers shall meet the 3-A Sanitary Standards
for Construction and Installation.
l) Pumps: Pumps used for milk and dairy
products shall be of the sanitary type and constructed to meet 3-A Sanitary
Standards. Unless pumps are specifically designed for effective cleaning in
place they shall be disassembled and thoroughly cleaned after use.
m) Homogenizers: Homogenizers and high
pressure pumps of the plunger type shall meet the 3-A Sanitary
Standards.
n) New Equipment and
Replacements: New equipment and replacements, including all plastic parts and
rubber and rubberlike materials for parts and gaskets having product contact
surfaces, shall meet the 3-A Sanitary Standards. If equipment or replacements
are not approved by 3-A Sanitary Standards, such equipment and replacements
shall meet the general requirements of this section.
o) Vacuum Chamber: The vacuum chamber, as
used for flavor control, shall be made of stainless steel or other equally
noncorrosive metal. The unit shall be constructed to facilitate cleaning and
all product contact surfaces shall be accessible for inspection. It shall be
equipped with a vacuum breaker and a check valve at the product discharge line.
Only steam which meets the requirements for culinary steam shall be used (See
Section 785.410(d)).
The incoming steam supply shall be regulated by an automatic solenoid valve
which will cut off the steam supply in the event the flow diversion valve of
the HTST pasteurizer is not in the forward flow position. Condensers when used
shall be equipped with a water level control and an automatic safety shutoff
valve.