Ill. Admin. Code tit. 77, § 890.340 - Use of Joints
a) Clay Sewer
Pipe. Joints in vitrified clay pipe or between vitrified clay pipe and metal
pipe shall be made with a neoprene gasket and stainless steel bands or as
provided in Section 890.320(f), (g) or
(o), if applicable.
b) Concrete Sewer Pipe. Joints in concrete
sewer pipe or between concrete sewer pipe and metal pipe shall be made with a
neoprene gasket and stainless steel bands or as provided in Section
890.320(f), (g) or
(o), if applicable.
c) Cast Iron Pipe. A joint in cast iron water
supply pipe shall be made in accordance with Section
890.320(a) and
(b) or shall be a mechanical joint in
accordance with AWWA C151. Joints in cast iron soil pipe shall be made in
accordance with Section
890.320(a), (b), (n), (o) or
(p).
d) Screw Pipe to Cast Iron. Joints between
wrought iron, steel, brass, or copper pipe and cast iron pipe shall be either
caulked or threaded joints that are made as provided in Section
890.320(a) or
(b) and shall be made with proper adaptor
fittings.
e) Lead to Cast Iron,
Wrought Iron or Steel. Joints between lead and cast iron, wrought iron, or
steel pipe shall be made by means of wiped joints to a caulking ferrule,
soldering nipple, or bushing as provided in Section
890.320(c).
f) Copper Water Tube. Joints in copper tubing
shall be made with cast bronze or wrought copper pressure fittings, properly
soldered or brazed, or by means of compression or flared joints as provided in
Sections 890.320(d), (e), (h) and
(p)(2). Flared joints and compression
fittings shall not be installed underground except for water services, water
meter yokes, and stop box connections.
g) Plastic Pipe. Joints between plastic pipe
and non-plastic material shall be made only with an appropriate type adaptor as
provided in Section 890.320(l) and
890.330(g).
1) Plastic-Commingling. There shall be no
commingling of plastic materials within the same plumbing system except through
the use of proper adaptors or approved solvent as listed in Appendix A.Table A,
for connections transitioning from one material to another, only.
2) Plastic Pipe. Plastic pipe shall not be
installed in any tunnel or chase that contains uninsulated hot water, hot air
or steam piping that causes the ambient air temperature in the tunnel or chase
to exceed 180 degrees Fahrenheit.
h) Building Sewer Connections. An elastomeric
coupling seal conforming to ASTM C 425, ASTM C 443, ASTM C 564, ASTM D 4161,
ASTM F 477, ASTM D 3139, ASTM D 3212, or ASTM D 412 tests may be used to adapt
any two building sewer pipes for different materials or size changes. The
flexible couplings shall be attached to the pipe with stainless steel clamps or
bolts. The manufacturer's recommended method of installation shall be
followed.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.