Iowa Admin. Code r. 567-49.10 - Types of well construction
(1)
Drilled wells.
a.
Non-bedrock wells.
(1)
Casing depth. In no case shall less than 20 feet of permanent solid casing be
installed in wells drilled in unconsolidated materials. If the alluvial aquifer
where the water is to be drawn from is covered by less than 40 feet of low
permeability materials, the well screen shall be set at the bottom of the
waterbearing aquifer or at least 60 feet from the surface. Deeper depths may be
required if nitrate contamination is excessive. If more than 40 feet of low
permeability materials are present above the aquifer, the casing shall extend
down at least to the top of the aquifer.
(2) Grouting.
1. Grout shall be placed to a minimum depth
of 40 feet or along the full length of the casing where less than 40 feet of
casing is set. Grouting the full length of the casing below 40 feet may be
necessary to isolate any contaminated water lenses or aquifers.
2. If a layer of low permeability material at
least 5 feet thick is encountered less than 40 feet from the surface, the grout
may be terminated no less than 5 feet below the top of this low permeability
material, but in no case less than 20 feet from the ground surface.
3. Grout shall be placed in accordance with
49.11(3), except when driving casing. When driving casing, a cone-shaped
depression or temporary outer casing that is filled with bentonite products
must be maintained around the well casing. The bottom of the driven casing
shall be equipped with a drive shoe.
(3) Annular space.
1. The borehole diameter shall be at least
three inches greater than the outside diameter of the well casing to the
minimum grouting depth.
2. When
steel well casing pipe is installed using percussion methods, the annular space
shall be at least five inches greater than the outside diameter of the well
casing to a minimum depth of 25 feet.
(4) If the depth of casing is greater than 40
feet, the annular space below 40 feet may be filled with heavy drilling fluid
taken from the borehole as long as the top 40 feet of annular space is properly
grouted. In this case, the annular space below 40 feet shall be kept as small
as possible to avoid settling.
b.
Bored and augered non-bedrock
wells with concrete, fiberglass, or clay tile casing. The casing shall
be at least 18 inches in diameter and buried-slab construction is required.
(1) Casing.
1. The top of the concrete, fiberglass, or
vitrified clay pipe casing shall be terminated not less than 10 feet below
ground surface and extend to a minimum depth of 20 feet.
2. Casing shall be fitted with a reinforced
concrete, fiberglass, or steel plate, into which a watertight steel or
thermoplastic casing is firmly embedded in or connected to a pipe that is cast
or welded into the plate.
3. The
embedded casing shall be at least 5 inches in diameter and shall extend from
the plate to not less than 12 inches above established grade or the 100-year
flood level, whichever is higher.
4. A pitless adapter shall be installed below
frost depth on newly installed plastic or steel casing.
(2) Grout. A 12-inch grout seal shall be
poured over and around the plate.
(3) Annular space. The annular space between
the steel or thermoplastic casing and the borehole shall be backfilled with
clean compacted soil free of debris or large organic material. During the
backfilling process, the earth shall be thoroughly tamped to minimize settling.
Grading around the well shall then be accomplished in accordance with
49.9(2).
c.
Bedrock wells.
(1) Casing
depth. Casing shall extend to a depth of at least 40 feet and be seated in firm
rock. When the uppermost bedrock consists of creviced limestone or dolomite
that does not produce water, the casing shall extend through the creviced
formation, be seated in firm rock, and be properly grouted.
(2) Grouting.
1. For bedrock wells, full-length grouting of
the casing is strongly recommended. Grout shall be placed to a minimum depth of
40 feet in accordance with 49.11(3), except when driving casing using
percussion or casing-hammer/rotary drilling.
2. When driving casing, a cone-shaped
depression or temporary outer casing that is filled with bentonite products
shall be maintained around the outside of the casing. The bottom of the driven
casing shall be equipped with a drive shoe.
3. If a layer of low permeability material at
least 5 feet thick is encountered less than 40 feet from the surface, the grout
may be terminated no less than 5 feet below the top of this low permeability
material, but in no case less than 20 feet from the ground surface.
4. Where local conditions warrant, the
administrative authority may require more extensive grouting to protect any
aquifer(s) that are penetrated.
(3) Annular space.
1. The borehole shall be at least three
inches greater than the outside diameter of the well casing for the upper 40
feet or the minimum grouting depth.
2. When steel casing pipe is installed using
percussion, or casing-hammer/rotary methods, the annular space shall be at
least five inches greater than the outside diameter of the well casing to a
minimum depth of 25 feet.
3. When
bedrock wells are full-length pressure-grouted through the casing, the borehole
diameter shall be three inches larger than the outside diameter of the casing
for the minimum depth of at least 25 feet.
(4) If the depth of casing is greater than 40
feet, the annular space below 40 feet may be filled with heavy drilling fluid
taken from the borehole as long as the top 40 feet of annular space is properly
grouted. In this case, the annular space below 40 feet shall be kept as small
as possible to avoid settling.
(5)
In fractured rock, where circulation of slurry cannot be maintained, grouting
may be done with bentonite chips. The chips shall be hydrated with one gallon
of water per bag of bentonite.
(2)
Driven, direct push, and
sandpoint wells. Well construction in sandy areas with a high water
table is not recommended for potable water supplies. These types of wells shall
meet the requirements of this chapter, except for casing depth and grouting
requirements.
(3)
Flowing
artesian wells.
a. Drilling
operations shall extend into but not through the formation confining the water.
The casing shall be installed and the annular space full-length
pressure-grouted and allowed to set. After the grout is set, the drill hole
shall be extended into the confined water-bearing formation.
b. Flow control from the well shall be
provided by valved pipe connections or a receiving tank set at an altitude
corresponding to that of the artesian head. Under no circumstances shall the
water flow uncontrolled to waste.
c. A direct connection between the discharge
pipe and a receiving tank, sewer, or other source of contamination is
prohibited.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
All
(1) Installing a liner. If the reconstruction will involve the placement of a liner, the certified well contractor must then determine whether the proposed reconstruction will be done in order to correct a health-related problem . The work to be performed must then be done in accordance with paragraph"a " or "b " below.
a. Standards for installation of a liner to correct a health-related problem .
(1) The liner shall have a minimum of two sets of centering guides to allow the proper placement of grout . In no case shall the liner be driven into place.
(2) The liner shall extend to the ground surface or top of the pitless adapter .
(3) The annular space between the old casing and the liner shall be pressure-grouted in place throughout its entire length using an approved grout .
b. Standards for installation of a liner to correct a problem that is not health-related.
(1) The liner shall extend at least ten feet above the static water level or, if a caving zone is present, shall extend above this region.
(2) The liner may be pressure-grouted in place if there is a sufficient annular space for proper application of the grout .
c. Liner material standards. Liners must meet well casing standards as defined in 49.9(1). Liners may be composed of either steel or thermoplastic with a minimum inside diameter of 4 inches. Steel liners must be new and have a minimum wall thickness of. 188 inches. Plastic liners must have a standard dimension ratio of 26 or less or a schedule rating of SCH 40 or SCH 80. If the installation does not meet the definition of a liner, then casing material shall be used.
(2) Upper terminus . All well reconstruction performed on the upper terminus of a well must meet the standards of this chapter.