Iowa Code r. 567-114.22 - Monitoring well siting requirements
(1)
Downgradient monitoring
wells. Downgradient monitoring wells must be located to provide a high
level of certainty that releases of contaminants from the site can be promptly
detected. Downgradient monitoring wells shall be placed along the site
perimeter, within 50 feet of the planned liner or waste boundary unless site
conditions dictate otherwise, downgradient of the facility with respect to the
hydrologic unit being monitored. For those facilities which are long-term,
multiphase operations, the department may establish temporary waste boundaries
in order to define locations for monitoring wells. The convergence of
groundwater paths to minimize the overall length of the downgradient dimension
may be taken into consideration in the placement of downgradient monitoring
wells.
(2)
Water table
wells. At least three downgradient water table monitoring wells shall
be installed at each facility. The maximum spacing between wells shall be 600
feet.
(3)
Uppermost aquifer
monitoring wells. If different from water table monitoring wells, at
least three uppermost aquifer monitoring wells shall be installed at each
facility. Uppermost aquifer monitoring wells shall be spaced no more than 600
feet apart. If the uppermost aquifer is located more than 50 feet below the
water table, this requirement may be relaxed, although at least one
downgradient uppermost aquifer monitoring well will be required.
(4)
Other downgradient monitoring
wells. Additional downgradient monitoring wells will be required if
the water table and uppermost aquifer monitoring wells do not intercept most
vertical flow paths from the site. In such situations, monitoring wells shall
be placed at the appropriate depths to intercept the remaining flow paths and
shall be spaced at no more than 600 feet apart.
(5)
Upgradient monitoring
wells. Upgradient monitoring wells shall not be affected by the site.
At least one upgradient monitoring well shall be installed into each stratum
being monitored by downgradient monitoring wells. If it is not possible to
actually locate a monitoring well upgradient of the site, the well shall be
placed as near the site as feasible without being affected by the
site.
(6)
Monitoring point
identification system. The various types of monitoring points shall be
identified as follows:
a. Monitoring Well MW#
_______
b. Surface Water Monitoring
Point SW# _______
c. Piezometer PZ#
_______
Each monitoring point must have a unique number, regardless of the type of monitoring point, and that number must never change.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.