Iowa Code r. 567-115.15 - Soil investigation
(1)
Soil borings.
a.
Number of borings. A sufficient number of soil borings shall
be made to accurately identify the hydrogeologic variations of the site. For
new sites, the minimum number of borings required is 10 for sites of less than
10 acres, 20 for sites of 10 to 50 acres, and 20 plus an additional boring for
every 10 acres above 50 acres for sites larger than 50 acres. Fewer borings may
be needed for existing sites, depending on previous work done at the site.
Also, no borings will be required in existing fill areas. The department may
require additional borings based on the geological complexity of the
site.
b.
Depth of
borings. All borings must extend a minimum of 25 feet deep and at
least 10 feet deep below the water table. However, borings in proposed fill
areas shall be terminated 10 feet above the uppermost aquifer or be grouted to
provide such separation. At least half the borings located outside the existing
or proposed fill area shall extend 10 feet into the uppermost aquifer, 50 feet
below the water table, or 10 feet into bedrock. At least one boring shall
extend 10 feet into bedrock or 100 feet below the lowest ground surface
elevation.
c.
Boring
method. Borings shall comply with the applicable portions of rule
567-115.23 (455B). The preferred
boring method is hollow stem auger, although it may be necessary to use other
methods at greater depths and in bedrock. When wet drilling methods are used
for boring in which monitoring wells or piezometers are installed, the drilling
fluid and methods and development procedures shall be approved by and
documented with the department.
d.
Assurance that soil boring samples have been taken at the
site. The soil boring samples must be kept by the permit applicant
until the permit is issued and must be made available to the department if the
department requests them.
(2)
Soil samples. Samples
shall be collected at 5-foot intervals and at every change in stratum. These
samples shall be obtained using a split spoon sampler and the procedures of the
standard penetration test, conducted in accordance with American Society of
Testing and Materials (ASTM) Standard D1586. This test simply counts the blows
of a 140-pound hammer falling 30 inches on the sampler per foot penetration of
the sampler. A minimum of one undisturbed Shelby tube sample shall be obtained
in the uppermost cohesive stratum at or below the lowest depth at which solid
waste will be disposed of. Shelby tube sampling shall be in accordance with
ASTM Standard D1587. Samples shall be clearly marked, preserved, and maintained
for future inspection. Samples selected for laboratory analysis shall be
preserved and transported to the laboratory in accordance with ASTM Standard
D422.
(3)
Laboratory test of
discrete soil samples. Laboratory tests of discrete soil samples shall
be conducted to correlate strata between soil borings, obtain permeability data
on each stratum, and design monitoring wells.
a.
Permeability tests.
Permeability tests using a constant-head or falling-head permeameter shall be
run on a minimum of one sample from each Shelby tube sample. Each sample shall
be from a different soil boring representing a different area of the
site.
b.
Grain size
distribution. Grain size distribution tests shall be conducted on a
minimum of one sample from each distinct stratum. Analysis shall be conducted
in accordance with ASTM Standards D422 and D1140. Estimates of permeability
shall be developed for each sample tested based on grain size distribution and
standard penetration blow counts.