Kan. Admin. Regs. § 28-35-290 - Reports of incidents or of lost or stolen sources
(a) Each licensee
or registrant shall provide a written report of all events involving
radiography devices and licensed material as specified in K.A.R. 28-35-184b,
K.A.R. 28-35-228a, K.A.R. 28-35-229a, and K.A.R. 28-35-230a.
(b) In addition to the requirements in
subsection (a), each licensee or registrant shall provide a written report to
the department within 30 days after the occurrence of any of the following
incidents involving radiographic equipment:
(1) Unintentional disconnection of the source
assembly from the control cable;
(2) inability to retract the source assembly
to its fully shielded position and secure the source assembly in this position;
or
(3) failure of any component
that is critical to safe operation of the device to perform its intended
function.
(c) Each
licensee or registrant shall include the following information with each report
submitted under subsection (b):
(1) A
description of the equipment problem;
(2) a description of the cause of each
incident, if known;
(3) the name
of the manufacturer and the model number of the equipment involved in the
incident;
(4) the place, time, and
date of incident;
(5) a
description of the actions taken to establish normal operations;
(6) a description of all corrective actions
taken or planned to prevent reoccurrence; and
(7) a description of the qualifications of
the personnel involved in the incident.
(d) Each report of overexposure submitted
pursuant to these regulations that involves failure of the safety components of
radiography equipment shall also include the information specified in
subsection (c).
(e) Each licensee
or registrant conducting radiographic operations or storing sources of
radiation at any location not listed on the license or registration for a
period in excess of 180 days in a calendar year shall notify the department
before exceeding the 180 days.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.