Kan. Admin. Regs. § 28-45-20 - Workovers
(a) Each permittee
shall submit a written workover plan to the department for the secretary's
review and consideration for approval, at least 10 days before any workover
begins. The workover plan shall include the following information:
(1) A description of any testing or log that
will be performed as part of the workover; and
(2) a schedule of when the workover will be
conducted.
(b) A
permittee shall not be required to submit a work-over plan for routine logging
or maintenance or for the replacement of gauges, sensors, or valves.
(c) Written authorization to initiate work
may be issued by the department if the permittee has met the requirements of
this article of the department's regulations.
(d) Each permittee shall ensure that a
blowout preventer with a pressure rating of more than the pressures anticipated
to be encountered is used during each workover.
(e) Each permittee shall ensure that a
lubricator with a pressure rating of more than the pressures anticipated to be
encountered is used when a lubricator unit is required.
(f) Each permittee shall provide to the
person completing the log or initiating a workover all relevant information
concerning the status and condition of the storage well and cavern before
initiating any work.
(g) Each
permittee shall submit a written summary report of the workover to the
department for review, within 90 days of completion. The report shall include
the following information:
(1) A summary page
with all pertinent well data on a form provided by the department;
(2) a description of the objectives and goals
for the workover;
(3) a written
description of the work that was completed during the workover;
(4) preworkover and postworkover
schematics;
(5) a written summary
and conclusions regarding the workover;
(6) a copy of each associated log and each
mechanical integrity test performed during the workover; and
(7) a written interpretation of each log and
results for each mechanical integrity test.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.