06-096 C.M.R. ch. 125, § 4 - Control Device Operation and Maintenance
A.
Carbon Adsorbers
1 All exhaust from the washer, dryer, filter
purification system, holding "tanks" and attendant piping and valves must be
routed through the carbon adsorber. The carbon adsorber shall be operated at an
air flow capacity at least equal to the unrestricted total exhaust gas flow
rate of the dry cleaning machines.
2 Any dry cleaner which uses a carbon
adsorber to comply with this Chapter must regenerate the carbon bed in
accordance with the manufacturer's recommendations, except that the carbon bed
shall be regenerated no less than either weekly, or after twenty five (25)
loads, whichever period is greater.
a The 100
ppmv emission limit from the carbon adsorber must be met regardless of the
regeneration requirements of this Section
b The carbon adsorber must not be bypassed to
the atmosphere during regeneration.
B.
Refrigerated Condenser System
1 A refrigerated condenser system must be
installed on a dry-to-dry machine and reclaimer, provided that the
dryer/condenser system is closed to the atmosphere except when articles are
being loaded or unloaded at which time a door fan is activated that draws air
into the dryer.
2 The condenser
shall be monitored in accordance with subsection 5(B). The temperature at the
dryer/condenser outlet must be less than or equal to 45°F. This condenser
shall be monitored in accordance with section 5(B).