Rule 8.
(1) If field
analysis shows that the vapor pressure is 7.0 or less, then the gasoline will
be deemed to be in compliance with the requirements in section 3 of the
act.
(2) If field analysis shows
that the vapor pressure is above 7.0 psi, but is not more than 8.0 psi and the
gasoline contains between 9.0 and 10.0% ethanol by volume, then the gasoline
will be deemed to be in compliance with the vapor pressure requirements in
section 3 of the act.
(3) If field
analysis shows the vapor pressure is between 7.0 and 7.5 psi, then the bills of
lading and other delivery documents are subject to review by the department to
determine the source of the gasoline. If the bills of lading and other delivery
documents show RFG was delivered and the gasoline is registered with the
department under section 6(12) of the act and meets all of the specifications
in the registration, then the gasoline will be deemed to be in compliance with
the requirements of section 3 of the act.