Mich. Admin. Code R. 299.9604 - Facility design and operating standards
Rule 604. The owner or operator of a treatment, storage, or disposal facility shall design, construct, operate, and maintain all the following:
(a) A run-on control system capable of preventing flow onto the active portions of the facility during peak discharge from not less than a 24-hour, 25-year storm.
(b) A runoff management system to collect and control not less than the water volume resulting from active portions of the facility from a 24-hour, 100-year storm.
(c) Systems to prevent hazardous waste or hazardous waste constituents from escaping into the soil, directly or indirectly into surface water or groundwaters, or uncontrolled into drains or sewers.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
Rule 604. The
(a) A run-on control system capable of preventing flow onto the active portions of the facility during peak discharge from at least a 24-hour, 25-year storm.
(b) A runoff management system to collect and control at least the water volume resulting from active portions of the facility from a 24-hour, 100-year storm.
(c) Systems to prevent hazardous waste or hazardous waste constituents from escaping into the soil, directly or indirectly into surface water or groundwaters, or uncontrolled into drains or sewers.