Mich. Admin. Code R. 324.410 - Casing other than surface casing
Rule 410.
Table 410 Minimum Hole Size
| Minimum hole Size | ||
| Casing size | Minimum hole size | |
| outside diameter (O.D.)-inches | inches | outside diameter - |
| Up to 7 O.D. | 1 1/2 | Casing O.D. + |
| More than 7 O.D. | 2 | Casing O.D. + |
| More than 10 3/4 O.D. | 3 | Casing O.D. + |
An exception to the minimum hole size as shown in table 410 may be granted by the supervisor or authorized representative of the supervisor, upon a written request by the permittee or applicant, if it is determined that the proposal provides proper sealing of the well. The supervisor or authorized representative of the supervisor may require a larger hole size for the surface hole than the size shown in table 410 in order to prevent waste.