Mich. Admin. Code R. 325.5272 - Appendix C. Radioactive surface contamination guides
Rule 272.
| Application |
Alpha(dpm/100 cm2) |
Beta/Gamma* |
||
|
Total |
Removable |
|||
|
Total (mR/hr) |
Removable (dpm/100 cm2) |
|||
|
Restricted Area |
||||
|
Basic Guide |
25,000 (max) |
500 |
1.0 |
5,000 |
|
5,000 (avg) |
||||
|
Clean Area |
1,000 |
100 |
0.5 |
1,000 |
|
Non-Restricted Area |
||||
|
Skin, Personal Clothing |
500 |
N.D.** |
0.1 |
N.D.** |
|
Release of Material or Facilities |
2,500 (max) |
100 |
0.2 |
1,000 |
|
500 (avg) |
||||
*Measured at 1 cm from the surface
**N.D. - non-detectable
NOTES TO APPENDIX C
It should be emphasized that because of the wide range of physical factors, no one value (of the few which can be incorporated in a standard) can relate health effects to contamination levels in all the diverse situations in which contamination is measured. Accordingly, standards for contamination levels must be used as guides (or decision levels). The above levels shall therefore be applied with the following guidance: