Mich. Admin. Code R. 339.5248 - Miniature hobby locomotive boilers

Rule 248.

(1) At the initial inspection of a miniature hobby locomotive boiler, the owner shall provide the chief boiler inspector with design specifications and calculations for review and acceptance. If a boiler is approved for use, then the departments boiler division shall issue an identifying state number and a deputy boiler inspector shall attach it to the boiler.
(2) The owner shall ensure that a miniature hobby locomotive boiler has all the following minimum equipment:
(a) A pressure gauge graduated to approximately 1-1/2 times the operating pressure, but not more than 4 times the operating pressure.
(b) A means to extinguish the fire in the firebox if of a low water condition.
(c) Two means of feeding water to the boiler, 1 of which must be operable while the locomotive is stationary.
(d) A water level gauge glass located so that the top of the bottom nut of the gauge glass is approximately 10% of the distance between the crown sheet and the shell, but not less than 1/2 inch above the crown sheet.
(e) Two safety valves set at not more than 10% above the operating pressure for boilers fabricated after the effective date of the rules. The capacity of the safety valves must be equal to or greater than the calculated steam generated capacity of the boilers.
(3) The owner shall determine the maximum allowable working pressure of the miniature hobby locomotive boiler by calculation. In place of acceptable calculations, the owner shall subject the boiler to a hydrostatic pressure test of 1-1/2 times the owner specified operating pressure.
(4) Every 3 years, during the certificate inspection, the owner shall hydrostatically test the boiler to not more than 1-1/2 times the operating pressure.
(5) The departments boiler division shall develop procedures, policies, and check lists necessary to accomplish the inspections and tests required by these rules.
(6) Repairs to miniature hobby locomotive boilers are exempt from the licensing and permitting requirements of the act. Repair welding must be made pursuant to the requirements of ASME code section IX. Welding procedures and performance qualifications must be filed with the departments boiler division for review.

Notes

Mich. Admin. Code R. 339.5248
2023 MR 8, Eff. 5/3/2023

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.