Mich. Admin. Code R. 400.11307 - Toilet fixtures
Rule 307.
(1) Table
1 shall be used to determine the number of toilet fixtures needed for resident
camps, with showers being optional. When showers are provided as bath
facilities, hot water shall be available. Flush urinals may be substituted for
not more than 1/2 of the required number of toilets.
(2) Table 1 reads as follows:
Table 1
| Males or Females | ||||
| Persons of Each Sex to | Male Toilets | Female Toilets | Lava-Be Served tories | Showers |
| 1 - 10 | 1 | 1 | 1 | 1 |
| 11- 20 | 2 | 2 | 1 | 1 |
| 21- 40 | 3 | 3 | 2 | 2 |
A resident camp having a capacity of more than 40 persons shall provide additional facilities for each 20 persons or fraction thereof in accordance with table 1.
(3)
The number of persons listed in table 1 shall include staff members, unless
separate toilet facilities are provided for their use.
(4) A privy, outhouse, or chemical closet
used as a means of sewage disposal for a camp shall comply with section 12771
of Act No. 368 of the Public Acts of 1978, as amended, being S333.12771 of the
Michigan Compiled Laws. The bottom of the pit of an earth privy shall be not
less than 2 feet above the known high groundwater table. In a location where
this is not feasible, a watertight vault shall be
utilized.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.