Mich. Admin. Code R. 408.10563 - Button guide stabilization systems

Rule 563.

(1) Guide buttons shall be coordinated with platform-mounted equipment.
(2) Guide buttons shall be located horizontally on the building face to allow engagement of each of the guide tracks mounted on the platform.
(3) Guide buttons shall be located in vertical rows on the building face for proper engagement of the guide tracks mounted on the platform.
(4) Two guide buttons shall engage each guide track at all times, except for the initial engagement.
(5) Guide buttons that extend beyond the face of the building shall be free of sharp edges or points. Where cables, ropes, and lifelines may be in contact with the building face, guide buttons shall not interfere with their handling or operation.
(6) Guide buttons, connections, and seals shall be capable of sustaining, without damage, at least the weight of the platform or the guide tracks or guide track connectors shall have provisions to prevent the platform and its attachments from transmitting the weight of the platform to the guide buttons, connections, and seals. In either case, the minimum design load shall be 300 pounds (1334 n) per building anchor.

Notes

Mich. Admin. Code R. 408.10563
1979 AC; 1992 AACS

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.