Mich. Admin. Code R. 408.10575f - Button-guide stabilized platforms
Rule 575f.
(1)
The button-guide stabilized platform shall be in compliance with the
requirements of R 408.10575b(1) to (13).
(2) Each guide track on the button-guide
stabilized platform shall engage a minimum of 2 guide buttons during any
vertical travel of the platform after the initial button engagement.
(3) Each guide track on a button-guide
stabilized platform that is part of a roof-rigged system shall be provided with
a storage position on the platform.
(4) Each guide track on the button-guide
stabilized platform shall be sufficiently maneuverable by platform occupants to
permit easy engagement of the guide buttons and easy movement into and out of
the guide track's storage position on the platform.
(5) Two guide tracks shall be mounted on the
button-guide stabilized platform and shall provide continuous contact with the
building face.
(6) The
load-carrying components of the button guide stabilization system that transmit
the load into the platform shall be capable of supporting the weight of the
platform or provision shall be made in the guide track connectors or platform
attachments to prevent the weight of the platform from being transmitted to the
platform attachments.