Mich. Admin. Code R. 408.10636 - Maximum travel distance to exits
Rule. 636. Table 1 reads as follows:
| TABLE 1 | |||
| Type of occupancy | Maximum travel distance to exits (in feet) | Dead-end limits (in feet) | |
| Unsprinkler ed | Sprinklered | ||
| Mercantile, ordinary hazard | 150 | 250 | 50 |
| Mercantile, high hazard | 75 | 75 | 0 |
| Business | 200 | 300 | 50 |
| Industrial | 200 | 250 | 50 |
| Industrial, high hazard | 0 | 75 | 0 |
| Storage, low and ordinary hazard | 200 | 400 | 100 |
| Storage, high hazard | 75 | 100 | 0 |
| Hotels | 100 | 200 | 50 |
| Note: For miscellaneous structures, See R 408.10691 to R 408.10697 | |||