Mich. Admin. Code R. 408.11412 - Maintenance
Rule 1412.
(1)
Lubrication shall be accomplished by 1 of the following methods:
(a) Scheduling when a conveyor can be shut
off and locked out.
(b) Automatic
pressure or gravity feed system.
(c) Extension pipe leading to an area outside
of guards or away from any hazard.
(2) Lubrication must comply with General
Industry Safety Standard Part 7 "Guards for Power Transmission," as referenced
in
R
408.11402.
(3) Repairs or clean up, where unexpected
motion would cause injury, shall be done when power is off and locked
out.
(4) A walkway or catwalk along
a conveyor shall be maintained clear of spills or other obstructions which may
be a slipping or tripping hazard.
(5) A flammable cleaning fluid used in
splicing of belts shall be kept in a safety container. Welding, cutting, or
smoking shall not be permitted in the area where flammable cleaning fluids are
being used.