Mich. Admin. Code R. 408.12462 - Point of operation guards
Rule 2462.
(1)
A point of operation guard shall meet the following design, construction,
application, and adjustment requirements:
(a)
It shall prevent entry of hands or fingers into the point of operation by
reaching through, over, under, or around the guard.
(b) It shall conform to the maximum
permissible openings of table 1 and figure 1, except that a barrier guard may
have feed holes for the stock, which shall be of such size and distance from
the die as to prevent entry of a hand or finger of each operator into the point
of operation or nip point.
(c) It
shall, in itself, create no pinch point between the guard and moving machine
parts.
(d) It shall utilize
fasteners not readily removable by the operator so as to minimize the
possibility of misuse or removal of essential parts.
(e) It shall facilitate its
inspection.
(f) It shall offer
maximum visibility of the point of operation consistent with the other
requirements.
(2) A die
enclosure guard shall be attached to the die shoe or stripper in a fixed
position.
(3) A fixed barrier guard
shall be attached securely to the frame of the press or to the bolster
plate.
(4) An interlocked press
barrier guard shall be attached to the press frame or bolster, and shall be
interlocked with the press clutch control so that the clutch cannot be
activated unless the guard itself, or the hinged or movable sections of the
guard, are in position to conform to the requirements of table 1 and figure
1.
(5) The hinged or movable
sections of an interlocked press barrier guard shall not be used for manual
feeding. The guard shall prevent opening of the interlocked section and
reaching into the point of operation prior to die closure or prior to the
cessation of slide motion. See
R
408.12463(2) regarding manual feeding
through interlocked press barrier devices.
(6) The adjustable barrier guard shall be
securely attached to the press bed, bolster plate, or die shoe, and shall be
adjusted and operated in conformity with table 1 and figure 1 and the
requirements of this rule.
Adjustments shall be verified before the press is returned to production operations by authorized personnel whose qualifications include a knowledge of the provisions of table 1 and figure 1 and the requirements of this rule.
(7) A point of operation enclosure which does
not meet the requirements of this rule and table 1 and figure 1 shall be used
only in conjunction with point of operation devices.