Mich. Admin. Code R. 408.12620 - Chip guards; protection from coolant splash
Rule 2620.
(1)
Chips which create a hazard shall be controlled by a chip guard that is located
between the point of operation and any employee within range.
(2) If a machine uses a coolant, an employee
shall be protected from coolant splash.
(3) Chips, dust, or sludge shall be removed
by brush, tools, or mechanical means. Where air pressure is used, the discharge
of a hand-held nozzle shall be less than 30 pounds per square inch under a
static flow condition.