Mich. Admin. Code R. 408.13395a - General requirements for personal fall protection systems
Rule 3395a.
(1) An employer shall ensure that personal
fall protection systems meet the requirements contained in this
standard.
(2) Connectors shall be
drop forged, pressed or formed steel, or made of equivalent
materials.
(3) Connectors must have
a corrosion-resistant finish, and all surfaces and edges shall be smooth to
prevent damage to interfacing parts of the system.
(4) When vertical lifelines are used, each
employee shall be attached to a separate lifeline.
(5) Lanyards and vertical lifelines shall
have a minimum breaking strength of 5,000 pounds (22.2 kN).
(6) Self-retracting lifelines and lanyards
that automatically limit free fall distance to 2 feet (0.61 m) or less shall
have components capable of sustaining a minimum tensile load of 3,000 pounds
(13.3 kN) applied to the device with the lifeline or lanyard in the fully
extended position.
(7) A competent
person or qualified person shall inspect each knot in a lanyard or vertical
lifeline to ensure that it meets the requirements of subrules (5) and (6) of
this rule, before any employee uses the lanyard or lifeline.
(8) D-rings, snaphooks, and carabiners shall
be capable of sustaining a minimum tensile load of 5,000 pounds (22.2
kN).
(9) D-rings, snaphooks, and
carabiners shall be proof tested to a minimum tensile load of 3,600 pounds (16
kN) without cracking, breaking, or incurring permanent deformation. The gate
strength of snaphooks and carabiners shall be proof tested to 3,600 lbs. (16
kN) in all directions.
(10)
Snaphooks and carabiners shall be the automatic locking type that require at
least 2 separate, consecutive movements to open.
(11) Snaphooks and carabiners shall not be
connected to any of the following unless they are designed for such
connections:
(a) Directly to webbing, rope, or
wire rope.
(b) To each
other.
(c) To a D-ring to which
another snaphook, carabiner, or connector is attached.
(d) To a horizontal life line.
(e) To any object that is incompatibly shaped
or dimensioned in relation to the snaphook or carabiner such that unintentional
disengagement could occur when the connected object depresses the snaphook or
carabiner gate, allowing the components to separate.
(12) An employer shall ensure that each
horizontal lifeline is as follows:
(a) Is
designed, installed, and used under the supervision of a qualified
person.
(b) Is part of a complete
personal fall arrest system that maintains a safety factor of at least
2.
(13) Anchorages used
to attach to personal fall protection equipment shall be independent of any
anchorage used to suspend employees or platforms on which employees work.
Anchorages used to attach to personal fall protection equipment on mobile work
platforms on powered industrial trucks shall be attached to an overhead member
of the platform, at a point located above and near the center of the
platform.
(14) Anchorages, except
window cleaners belt anchors covered by R 408.13395d to R 408.13395g, shall be
able to do either of the following:
(a)
Capable of supporting at least 5,000 pounds (22.2 kN) for each employee
attached.
(b) Designed, installed,
and used, under the supervision of qualified person, as part of a complete
personal fall protection system that maintains a safety factor of at least
2.
(15) Travel restraint
lines shall be capable of sustaining a tensile load of at least 5,000 pounds
(22.2 kN).
(16) Lifelines must not
be made of natural fiber rope. Polypropylene rope must contain an ultraviolet
(UV) light inhibitor.
(17) Personal
fall protection systems and their components shall be used exclusively for
employee fall protection and not for any other purpose, such as hoisting
equipment or materials.
(18) A
personal fall protection system or its components subjected to impact loading
shall be removed from service immediately and not used again until a competent
person inspects the system or components and determines that it is not damaged
and safe for use for employee personal fall protection.
(19) Personal fall protection systems shall
be inspected before initial use during each workshift for mildew, wear, damage,
and other deterioration, and defective components shall be removed from
service.
(20) Ropes, belts,
lanyards, and harnesses used for personal fall protection shall be compatible
with all connectors used.
(21)
Ropes, belts, lanyards, lifelines, and harnesses used for personal fall
protection shall be protected from being cut, abraded, melted, or otherwise
damaged.
(22) An employer shall
provide for prompt rescue of each employee in the event of a fall.
(23) Personal fall protection systems shall
be worn with the attachment point of the body harness located in the center of
the employee's back near shoulder level. The attachment point may be located in
the pre-sternal position if the free fall distance is limited to 2 feet (0.6 m)
or less.