Mich. Admin. Code R. 408.14525 - Maintenance and servicing
Rule 4525.
(1)
A power source of a machine or equipment to be repaired or for die repair shall
be locked out by each employee doing the work if unexpected motion would cause
injury. Residual pressure shall be relieved or isolated before and during the
work if unexpected motion would cause injury. The means of isolation shall also
be locked out.
(2) An employee who
services or sets up a hot chamber die casting machine shall do either of the
following:
(a) Pull the plunger from the goose
neck.
(b) Insert a safety bar to
block action of the plunger.
(3) During service or set up, an extractor
shall be locked out as prescribed in subrule (1).