Mich. Admin. Code R. 408.15222 - Walking-working surfaces
Rule 5222.
(1)
An aisle or floor work area shall be kept free of protruding objects, holes,
and loose boards.
(2) A floor at
the operator's station of a machine shall be maintained free of any slip or
trip hazard.
(3) A floor shall be
capable of sustaining the imposed load.
(4) An aisle, passageway, roadway, or dock
shall be of such width as to provide for the safe passage of employees or
vehicles, or both. A dock where powered industrial trucks are used shall be
provided with a guard or bumper along its perimeter, except at loading or
unloading points, to prevent overrun.
(5) A swinging door shall be provided with a
window in each section. The window shall be of clear safety glass or equivalent
material or protected against breakage.
(6) Where a doorway opens upon a railroad
track or upon a tramway or dock over which vehicles travel, a barrier or other
warning device shall be placed to prevent employees from stepping into moving
traffic.
(7) Where elevated
platforms are used routinely on a daily basis, the elevated platforms shall be
equipped with stairways or fixed ladders that comply with General Industry
Safety and Health Standard Part 2 "Walking-Working Surfaces," as referenced in
R 408.15209.
(8) Stairways shall be constructed in
accordance with General Industry Safety and Health Standard Part 2
"Walking-Working Surfaces," as referenced in
R 408.15209.
(9) In dry kilns and facilities, a fixed
ladder complying with the requirements General Industry Safety and Health
Standard Part 2 "Walking-Working Surfaces," as referenced in
R 408.15209, or other adequate
means, shall be provided to permit access to the roof. Where controls and
machinery are mounted on the roof, a permanent stairway with standard handrail
shall be installed in accordance with General Industry Safety and Health
Standard Part 2 "Walking-Working Surfaces".